7 / 9 page ![]() The following is the discriminating algorithm be- tween fast and slow Vcc transients. The transient voltage clamp is normally set at 70V. If Vcc rises above the Vcc_ov=19V typ. over voltage shut- down threshold, both Td_ov_1 and Td_ov_2 tim- ers start. When the first timer stops (after 130 µs typ. delay) the clamp status is evaluated and locked. If the transient has been fast enough and the voltage clamp activated, then it remains 70V active until the second timer stops (after 1ms de- lay), then it deactivates by rising to 80V. If the transient has been slow and the voltage clamp unreached when the first timer stops, then it de- activates by rising to 80V. A new 70V clamp cycle may restart only by lowering Vcc below the 19V over voltage shutdown threshold. The VFB and VCOM input pins may connect to the Vcc or lower voltage during the power supply transients of Figs. 4 and 5. L9909 7/9 |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|