| データシートサーチシステム |
|
TSV620 データシート(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TSV620 データシート(HTML) 13 Page - STMicroelectronics |
|
13 / 24 page ![]() DocID14912 Rev 3 13/24 Document header RPN(s) Application information 24 3.4 Shutdown function (TSV620) The operational amplifier is enabled when the SHDN pin is pulled high. To disable the amplifier, the SHDN pin must be pulled down to VCC-. When in shutdown mode, the amplifier output is in a high impedance state. The SHDN pin must never be left floating but tied to VCC+ or VCC-. The turn-on and turn-off times are calculated for an output variation of ±200 mV (Figure 16 and Figure 17 show the test configurations). Figure 16. Test configuration for turn-on time (Vout pulled down) Figure 17. Test configuration for turn-off time (Vout pulled down) Vcc-0.5V + - +Vcc DUT GND GND Vcc-0.5V + - +Vcc DUT GND GND Figure 18. Turn-on time, VCC = 5 V, Vout pulled down, T = 25 °C Figure 19. Turn-off time, VCC = 5 V, Vout pulled down, T = 25 °C Shutdown pulse Vout Vcc = 5V T = 25°C Time( s) Shutdown pulse Vout Vcc = 5V T = 25°C Time( s) |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|