2 / 2 page ![]() Conditions Parameter Test Conditions Min. Typ. Max. Unit Operating Temperature 0 40 70 °C Storage Temperature -40 85 °C Relative Humidity 5 95 % Operation temperature at 25°C, calculated per MIL-HDBK-217F 0.1M Hrs Derate linearly from 100% load at 40°C to 50% load at 70°C Approvals and Compliance Parameter Test Conditions Min. Unit Dielectric Withstanding Voltage for Primary to secondary Primary to secondary 4242 VDC Dielectric Withstanding Voltage for Primary to Ground Primary to ground 2121 VDC Isolation Resistance Test Voltage = 500VDC 50 MΩ EMI requirements for CISPR-22 Vin=220VAC B CLASS EMI requirements for FCC PART-15 Vin=110VAC B CLASS Mechanical and PIN out Note: 1. Dimensions are shown in mm & inch 2. Weight: 340gs approx. (Exclude the input cord) 3. Optional output connector. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|