6 / 23 page ![]() AXL E S3 DI8 DO4 2A M12 6P 8563_en_04 PHOENIX CONTACT 6 Limitation of the voltage induced on circuit interruption -28 V ... -17 V Output voltage when switched off max. 1 V Output current when switched off max. 20 µA Behavior with overload Auto restart Reverse voltage resistance to short pulses Reverse voltage proof Overcurrent shut-down min. 0.7 A Overload protection, short-circuit protection of outputs Electronic Electrical isolation/isolation of the voltage areas Test section Test voltage 24 V supply (communications power and sensor supply, digital inputs)/ bus connection (Ethernet 1) 500 V AC, 50 Hz, 1 min 24 V supply (communications power and sensor supply, digital inputs)/ bus connection (Ethernet 2) 500 V AC, 50 Hz, 1 min 24 V supply (communications power and sensor supply, digital inputs)/FE 500 V AC, 50 Hz, 1 min Bus connection (Ethernet 1)/FE 500 V AC, 50 Hz, 1 min Bus connection (Ethernet 2)/FE 500 V AC, 50 Hz, 1 min Bus connection (Ethernet 1)/bus connection (Ethernet 2) 500 V AC, 50 Hz, 1 min 24 V supply (actuator supply, digital outputs)/ 24 V supply (communications power and sensor supply, digital inputs) 500 V AC, 50 Hz, 1 min 24 V supply (actuator supply, digital outputs)/bus connection (Ethernet 1) 500 V AC, 50 Hz, 1 min 24 V supply (actuator supply, digital outputs)/bus connection (Ethernet 2) 500 V AC, 50 Hz, 1 min 24 V supply (actuator supply, digital outputs)/FE 500 V AC, 50 Hz, 1 min Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g Conformance with EMC Directive 2004/108/EC Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B; 6 kV contact discharge, 8 kV air discharge Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A; Field intensity: 10 V/m Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV Transient surge voltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical) Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V Noise emission test as per EN 61000-6-4 Radio interference properties EN 55022 Class A Approvals For the latest approvals, please visit phoenixcontact.net/products. Digital outputs |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |