19 / 23 page ![]() AXL E S3 DI8 DO4 2A M12 6P 8563_en_04 PHOENIX CONTACT 19 14 Password (IDN S-0-00267) In the default setting some parameters of the device are write-protected with a password. If you try to change pass- word-protected parameters without lifting the write protec- tion, error 7009 hex is output via the service channel (opera- tion data is password write-protected). The password can be changed and the write protection can be activated or deactivated via IDN S-0-0267. Passwords can only comprise UTF8 characters without spaces and are stored retentively. The default password is PW170875. The list of password-protected parameters can be found in IDN S-0-0279. The following IDNs are password protected: 14.1 Change password To change the password, the currently active password, the new password, and, for confirmation, the new password again must be sent to the device, each separated by a space. Changing the password automatically activates write protection for all password-protected parameters. 14.2 Activate write protection There are three methods for activating password-protected write protection: – Switch the power supply off and back on. Once the de- vice is restarted, write protection is activated. – Overwrite the password parameter with something oth- er than the password. – Change the existing password. 14.3 Deactivate write protection The write protection is deactivated by overwriting the pass- word parameter with the current password. 15 IP address assignment The IP address is changed via the following IDNs: The IP address can be changed via the Sercos parameter S-0-1020. The subnet mask can be changed via parameter S-0-1021 and the gateway address via parameter S-0-1022. The IDN S-0-1048 is used to activate the IP address via Sercos. 16 Monitoring connection (connection setup, IDN S-0-1050.x.1) The following connection monitoring mechanisms are sup- ported (bit 0 and bit 1 of IDN S-0-1050.x.1): – Producer cycle, synchronous operation (00 bin) – Asynchronous operation without watchdog (10 bin) 17 Electronic rating plate (IDNs S-0-1300.x.y) The electronic rating plate comprises the IDNs S-0-1300.x.y. See the table in the “Sercos parameter” section. IDN Description S-0-1020 IP address S-0-1021 Subnet mask S-0-1022 Gateway address If the password is read via the service chan- nel, the device will send the password as a string with 3 “*” characters (UTF8 code 0x2A) if the write protection is activated or as a string with 3 “$” characters (UTF8-Code 0x24) if the write protection is deactivated and not as plain text. IDN Description S-0-1020 IP address S-0-1021 Subnet mask S-0-1022 Gateway address S-0-1048 Procedure Command - activation of the IP parameters All parameters are password-protected. For further information, please refer to the “Pass- word” section. The modified IP address parameters are not stored retentively on the device. In the case of a voltage reset, these parameters need to be re-transmitted. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |