14 / 78 page ![]() 2019 Microchip Technology Inc. DS20006153A-page 14 SST26VF016BEUI 5.1 No Operation (NOP) The No Operation command only cancels a Reset Enable command. NOP has no impact on any other command. 5.2 Reset-Enable (RSTEN) and Reset (RST) The Reset operation is used as a system (software) reset that puts the device in normal operating Ready mode. This operation consists of two commands: Reset-Enable (RSTEN) followed by Reset (RST). To reset SST26VF016BEUI, the host drives CE# low, sends the Reset-Enable command (66H), and drives CE# high. Next, the host drives CE# low again, sends the Reset command (99H), and drives CE# high, see Figure 5-1. The Reset operation requires the Reset-Enable com- mand followed by the Reset command. Any command other than the Reset command after the Reset-Enable command will disable the Reset-Enable. Once the Reset-Enable and Reset commands are suc- cessfully executed, the device returns to normal opera- tion Read mode and then does the following: resets the protocol to SPI mode, resets the burst length to 8 Bytes, clears all the bits, except for bit 4 (WPLD) and bit 5 (SEC), in the Status register to their default states, and clears bit 1 (IOC) in the configuration register to its default state. A device reset during an active Program or Erase operation aborts the operation, which can cause the data of the targeted address range to be cor- rupted or lost. Depending on the prior operation, the reset timing may vary. Recovery from a Write operation requires more latency time than recovery from other operations. See Table 8-2 on page 46 for Rest timing parameters. FIGURE 5-1: RESET SEQUENCE 5.3 Read (40 MHz) The Read instruction, 03H, is supported in SPI bus pro- tocol only with clock frequencies up to 40 MHz. This command is not supported in SQI bus protocol. The device outputs the data starting from the specified address location, then continuously streams the data output through all addresses until terminated by a low- to-high transition on CE#. The internal address pointer will automatically increment until the highest memory address is reached. Once the highest memory address is reached, the address pointer will automatically return to the beginning (wrap-around) of the address space. Initiate the Read instruction by executing an 8-bit com- mand, 03H, followed by address bits A[23:0]. CE# must remain active low for the duration of the Read cycle. See Figure 5-2 for Read Sequence. FIGURE 5-2: READ SEQUENCE (SPI) 2005262 F05.0 MODE 3 CLK SIO(3:0) CE# MODE 3 C1 C3 C2 C0 MODE 0 MODE 3 MODE 0 MODE 0 TCPH Note: C[1:0] = 66H; C[3:2] = 99H 20005262 F29.0 CE# SO SI SCK ADD. 01 2 3 4 5 6 7 8 ADD. ADD. 03 HIGH IMPEDANCE 15 16 23 24 31 32 39 40 70 47 48 55 56 63 64 N+2 N+3 N+4 N N+1 DOUT MSB MSB MSB MODE 0 MODE 3 DOUT DOUT DOUT DOUT |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |