42 / 161 page ![]() ZC ZC ZC ZC ZC ZC ZC ZC ZC ZC Phase Voltage A Phase Voltage B Phase Voltage C Figure 8-28. 120o commutation in Mixed Modulation Mode 8.3.10.2 Variable Commutation Variable commutation can be configured by setting COMM_CONTROL to 01b. 120o commutation may result in acoustic noise due to the long Hi-Z period causing some torque ripple in the motor. In order to reduce this torque ripple and acoustic noise, the MCT8317A uses variable commutation to reduce the phase current ripple at commutation by extending 120o driving time and gradually decreasing duty cycle prior to entering Hi-Z state. In this mode, the phase is Hi-Z between 30o and 60o and this window size is dynamically adjusted based on speed. A smaller window size will typically give better acoustic performance. Figure 8-29 shows 150o commutation with 30o window size. MCT8317A SLLSFQ2 – JANUARY 2023 www.ti.com 42 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: MCT8317A |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|