21 / 26 page ![]() Data Sheet ADR3625/ADR3630/ADR3650 THEORY OF OPERATION analog.com Rev. A | 21 of 26 Figure 66. Power Cycle Hysteresis HUMIDITY SENSITIVITY The ADR3625\ADR3630\ADR3650 are packaged in an MSOP. However, moisture absorption from the air into the package changes the internal mechanical stresses on the die, causing shifts in the output voltage. Figure 67 shows the effects of a step change in relative humidity on the output voltage over time. The humidity chamber is maintained at an ambient temperature of 25°C, while the relative humidity undergoes a step change from 30% to 70%. The relative humidity is maintained at 70% for the duration of the testing. Note that the output voltage shifts quickly compared to the overall settling time, following the step change in relative humidity. Figure 67. Change in Output Voltage vs. Time After Humidity Step (30% to 70% Relative Humidity (RH)) |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|