| データシートサーチシステム |
|
REF192 データシート(PDF) 22 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
REF192 データシート(HTML) 22 Page - Analog Devices |
|
22 / 26 page ![]() Data Sheet ADR3625/ADR3630/ADR3650 APPLICATIONS INFORMATION analog.com Rev. A | 22 of 26 BASIC VOLTAGE REFERENCE CONNECTION The basic configuration for the ADR3625\ADR3630\ADR3650 refer- ence is shown in Figure 68. For detailed information on connecting the bypass capacitors, see the Input and Output Capacitors section. Figure 68. Basic Reference Connection INPUT AND OUTPUT CAPACITORS Input Capacitors A 1 μF to 10 μF electrolytic or ceramic capacitor can be connected to the input to improve transient response in applications where the supply voltage can fluctuate. It is recommended to connect an additional 0.1 μF ceramic capacitor in parallel to reduce supply noise. Output Capacitors A COUT is required for stability and to filter out low level voltage noise. The minimum value of COUT is 0.1 μF and can go as high as 10 μF for stability. An additional 1 μF to 10 μF electrolytic or ceramic capacitor can be added in parallel to improve transient performance in response to sudden changes in load current. The larger the output capacitor, the lower the bandwidth of the output is, thus lowering the noise. However, increasing the output capacitor increases the settling time and decreases the response rate. The ADR3625\ADR3630\ADR3650 are stable with a variety of capacitor types, including ceramic, electrolytic (including polymer), tantalum, and film. Small surface-mount capacitors have low effec- tive series resistance (ESR) and take up little board space. Place and connect the output capacitor as close as possible to the VOUT FORCE pin. Use low ESR capacitors. START-UP TIME The start-up time is determined by the output capacitance and output load current. Figure 69 shows an example of the start-up response of the ADR3625 when stepping the supply voltage and Figure 70 shows an example of the start-up response of the ADR3625 when stepping the enable voltage. Figure 69. ADR3625 Start-Up Response (Input) Figure 70. ADR3625 Start-Up Response (Enable) |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |