8 / 18 page ![]() ELECTRONICS FCI Electronics Manual Part No. 415988-001 Issued: Date (03/12/99) Page 8 of 18 Rev. 05/07/01 ECR V10337 Revision B K\DCU\Manuals • • Check that the spring was not dislodged from the disconnect (box) portion of the terminal. • Check that the wire barrel seam is even and tightly closed. Figure 4. Correctly Crimped Terminal Next, obtain a crimp height micrometer and measure the areas of the terminal shown in Figure 5. If the crimp heights do not meet the specifications listed in “Specifications” on page 5, refer to the section for proper adjustment procedures of crimp height on page 15. Figure 5. Measuring Crimp Height of Terminal PDM: Rev:B Released STATUS: Printed: Dec 19, 2002 |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|