| データシートサーチシステム |
|
AS73211 データシート(PDF) 15 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
AS73211 データシート(HTML) 15 Page - OSRAM GmbH |
|
15 / 66 page ![]() Document Feedback AS73211 Functional Description Datasheet • PUBLIC DS000556 • v3-01 • 2018-Feb-07 65 │ 14 7 Functional Description Three internal photodiodes with different spectral sensitivity with three A/D converters. The irradiance responsivity Re and the time of conversion TCONV are user defined and determined by registers CREG1:GAIN and CREG1:TIME and should be adapted to the application of interest. At the end of each conversion, the digital equivalents of the filtered input light signal regarding to the sensors area are stored in the ou tput registers (MRES1 … MRES3). Additionally a temperature sensor works in parallel to the three optical channels, delivering the on-chip temperature at the end of conversion. The pin READY remains at low logic level all the time during the conversion. The rising edge and the following high logic level of READY signalize the end of conversion. Internal information related to the conversion is available in a status register, too. 7.1 Operational States The AS73211 operates in two different states “Configuration” and “Measurement”. The three least significant bits of the Operational State Register (OSR) as Device Operational State (DOS) defined the current state. After applying the power supply voltage including power-on reset or after software reset the AS73211 stays in Power Down state. It is ready to be programmed via I²C interface. Switching off Power Down (OSR:PD set to ‚0‘) the AS73211 starts up in Configuration state (CONFIG) or in Measurement state (MMODE) according to its DOS programming. 7.2 Configuration State This state enables the access to the configuration registers (CREG1, CREG2, CREG3). Irradiance responsivity Re and conversion time TCONV can be determined by settings of registers CREG1:GAIN and CREG1:TIME as well as the kind of measurement mode can be chosen via register CREG3:MMODE. A measurement is not possible in this state and therefore no access to any measurement result registers. 7.3 Measurement State In this state the light-to-digital conversion can be performed. The access to the output result registers is enabled, but at this time, there is no access possible to the configuration registers. Specific settings for the measuring task should be performed by programming the configuration registers before the measurement is started (see chapter 8.5). The change between Configuration and Measurement state can be performed by programming the DOS value of the operational state register OSR (see Figure 45). A change from Measurement state to Configuration state takes place immediately. Any active measurement is stopped and all output result registers and the status register are reset as well. |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |