| データシートサーチシステム |
|
AD9913/PCBZ1 データシート(PDF) 28 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9913/PCBZ1 データシート(HTML) 28 Page - Analog Devices |
|
28 / 32 page ![]() AD9913 Rev. 0 | Page 28 of 32 Bit(s) Bit Name Description 00 = In direct switch mode, use this setting for FSK. In linear sweep mode, the auxiliary accumulator is used for frequency sweeping. In programmable modulus mode, these bits must be 00. 13:12 Destination 01 = In direct switch mode, use this setting for PSK. In linear sweep mode, the auxiliary accumulator is used for phase sweeping. 11 Auxiliary Accumulator Enable 0 = auxiliary accumulator is inactive. 1 = auxiliary accumulator is active. 10 DC Output Active This bit is ignored if linear sweep is disabled (see CFR1 [11]). 0 = normal operating state. 1 = the output of the DAC is driven to full-scale and the DDS output is disabled. 9 Linear Sweep State Trigger Active 0 = edge triggered mode active. 1 = state triggered mode active. 8 Linear Sweep No-Dwell Active This bit is ignored if linear sweep is disabled (see CFR1[11]). 0 = when a sweep is completed, the device holds at the final state. 1 = when a sweep is completed, the device reverts to the initial state. 7 External Power-Down Mode 0 = the external power-down mode selected is the fast recovery power-down mode. In this mode, when the PWR_DWN_CTL input pin is high, the digital logic and the DAC digital logic are powered down. The DAC bias circuitry, comparator, PLL, oscillator, and clock input circuitry are not powered down. 1 = the external power-down mode selected is the full power-down mode. In this mode, when the PWR_DWN_CTL pin is high, all functions are powered down. This includes the DAC and PLL, which take a significant amount of time to power up. 6 Digital Power-Down 0 = the digital core is enabled for operation. 1 = the digital core is disabled and is in a low power dissipation state. 5 DAC Power-Down 0 = the DAC is enabled for operation. 1 = the DAC is disabled and is in its lowest power dissipation state. 4 Clock Input Power-Down 0 = normal operation. 1 = shut down all clock generation including the system clock signal going into the digital section. 3 LOAD SRR @ IO_UPDATE 0 = every time the linear sweep rate register is updated, the ramp rate timer keeps its operation until it times out and then loads the update value into the timer. 1 = the timer is interrupted immediately upon the assertion of IO_UPDATE and the value is loaded. 2 Autoclear Auxiliary Accumulator 0 = normal operation. 1 = the auxiliary accumulator is synchronously cleared (zero is loaded) for one cycle upon receipt of the IO_UPDATE sequence indicator. 1 Autoclear Phase Accumulator 0 = normal operation. 1 = the phase accumulator is synchronously cleared for one cycle upon receipt of the IO_UPDATE sequence indicator. 0 Enable Sine Output 0 = the angle-to-amplitude conversion logic employs a cosine function. 1 = the angle-to-amplitude conversion logic employs a sine function. |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |