24 / 38 page ![]() Watchdog L9001 24/38 DS12089 Rev 2 7 Watchdog The device hosts a watchdog control unit. The μC must trigger the watchdog with a toggle on WDI pin within a configurable time period tWDT (also called normal window) which depends on external capacitance at pin WDT and is specified as tWDT(Cwdt). The feedback of the watchdog control can be checked monitoring output pin WDO. Accuracy of the window (including internal spread) is shown in the table below with reference to the case a 47 nF cap is mounted: tWDT(Cwdt) = tWDT(47 nF) * Cwdt/47 nF As soon as L9001 is in ACTIVE mode and resets of the VDD regulators are high (only the enabled regulators are considered), the watchdog is switched on and opens a long window which is 10 times the normal window. If the watchdog is correctly served before the end of this window, subsequent normal windows are opened as described in Figure 6. In order to serve the watchdog, WDI must toggle from low state to high state. A correct toggle is recognized when high state at WDI lasts as long as tWDI_h and low state as short as tWDI_l; when there is a correct WDI toggle, a WDI internal flag is set. At the end of the timing window tWDT(Cwdt), the flag is checked and if it is set to 1, the system is working properly, the flag is reset to 0 and the cycle goes on. If the flag is still at 0, a watchdog failure is generated. It follows that more than one WDI toggle can occur in the time window. WDO is an open drain output (low active). In case of watchdog failure the output WDO is driven low for the specified time tWDO; the output WDO will be relased after this time unless the device enters latch mode (see Section 8.2 and Figure 6 for details). Watchdog failure is also counted as failure condition for LATCH mode enter after 4 consecutive failures as explained in Section 8. In software development mode (FLASH mode) watchdog is disabled. This can be done by forcing WDT>WDT_thi. The device can regain Active mode if WDT<WDT_tho; the function is also switched off when entering LOW POWER mode, and is switched on again when re- entering ACTIVE mode (see Section 8.1 for details) When WDT pin is connected to a fixed voltage, watchdog functionality is frozen, but regulators still function normally. Table 14. Watchdog parameters Symbol Parameter Test condition Min. Typ. Max. Unit tWDT(47nF) Watchdog timer window length reference working point tWDT with C(WDT) = 47 nF 35 40 45 ms tWDT_lw(47nF) Watchdog timer long window tWDT_lw with C(WDT) = 47 nF 350 400 450 ms tWDO WDO active pulse duration - - 16 - ms Cwdt WDT pin capacitor Application info 1 47 100 nF tWDI_h Minimum high level WDI duration to trigger WD - - 50 - μs tWDI_l Minimum low level WDI duration - 3 - 10 μs WDI_h WDI input high level threshold - - - 1.5 V WDI_l WDI input low level threshold - 1.05 - - V |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |