| データシートサーチシステム |
|
L9001 データシート(PDF) 35 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9001 データシート(HTML) 35 Page - STMicroelectronics |
|
35 / 38 page ![]() DS12089 Rev 2 35/38 L9001 Appendix A 37 Appendix A The following table summarizes what happens if a fault condition is detected in ACTIVE state indicating the next state and the behavior of FC, Refresh FC counter and thresholds. Table 20. Clarify transitions from and to ACTIVE mode Fail / Current status ACTIVE (no overtemperature & no CP undervoltage) ACTIVE (after overtemperature fault) ACTIVE (after CP undervoltage fault) ACTIVE (after overtemperature & CP undervoltage) VS undervoltage – SAFE state – FC = FC – Refresh FC threshold = default (30 s) – Refresh FC is not triggered when device comes back in ACTIVE – SAFE state – FC = FC – Refresh FC threshold = 30 s – Refresh FC restart from 0 when device comes back in ACTIVE – SAFE state – FC = FC – Refresh FC threshold = 100 ms – Refresh FC restart from 0 when device comes back in ACTIVE – SAFE state – FC = FC – Refresh FC threshold = 30 s – Refresh FC restart from 0 when device comes back in ACTIVE Overtemperature – SAFE state – FC = FC+1 – Refresh FC threshold = 30 s – Refresh FC is triggered when device comes back in ACTIVE – FC = FC+1 →SAFE state if FC < 4 – FC = FC+1 →SAFE state and the next clk cycle Latch state if FC = 4 – Refresh FC threshold = 30 s – Refresh FC restart from 0 if device comes back in ACTIVE – FC = FC+1 →SAFE state if FC < 4 – FC = FC+1 →SAFE state and the next clk cycle Latch state if FC = 4 – Refresh FC threshold replaced from 100 ms to 30 s – Refresh FC restart from 0 if device comes back in ACTIVE – FC = FC+1 →SAFE state if FC < 4 – FC = FC+1 →SAFE state and the next clk cycle Latch state if FC = 4 – Refresh FC threshold = 30 s – Refresh FC restart from 0 if device comes back in ACTIVE CP undervoltage – SAFE state – FC = FC+1 – Refresh FC threshold = 100 ms – Refresh FC is triggered when device comes back in ACTIVE – FC = FC+1 →SAFE state if FC < 4 – FC = FC+1 →SAFE state and the next clk cycle Latch state if FC = 4 – Refresh FC threshold = 30 s – Refresh FC restart from 0 if device comes back in ACTIVE – FC = FC+1 →SAFE state if FC < 4 – FC = FC+1 →SAFE state and the – next clk cycle Latch state if FC = 4 – Refresh FC threshold = 100 ms – Refresh FC restart from 0 if device comes back in ACTIVE – FC = FC+1 →SAFE state if FC < 4 – FC = FC+1 →SAFE state and the next clk cycle Latch state if FC = 4 – Refresh FC threshold = 30 s – Refresh FC restart from 0 if device comes back in ACTIVE |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |