| データシートサーチシステム |
|
ADGM3121BCCZ-R2 データシート(PDF) 30 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADGM3121BCCZ-R2 データシート(HTML) 30 Page - Analog Devices |
|
30 / 33 page ![]() Data Sheet ADGM3121 CRITICAL OPERATIONAL REQUIREMENTS analog.com Rev. 0 | 30 of 33 ► Avoid connecting capacitive terminations directly to the switch, as shown in Figure 83. A shunt capacitor can store a charge that can potentially lead to hot switching events when the switch opens or closes, affecting the lifetime of the switch. Figure 83. Avoid Large Capacitor Directly Connected to the Switch Mechanical Shock Precautions The ADGM3121 passes Group D mechanical shocks tests, as detailed in Absolute Maximum Ratings. These tests validate the robustness of the device to normal mechanical shocks. The device should not be used if dropped. To reduce excessive me- chanical shock and ESD events, avoid handling of loose devices, as outlined in Figure 84. Figure 84. Situations to Avoid During Handling |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|