40 / 56 page ![]() E5CD/E5ED 40 Operation Parameter Flow This section describes the parameters set in each level. Pressing the M (Mode) Key at the last parameter in each level returns to the top parameter in that level. Hold down the M Key to move through the parameters in reverse. Some parameters may not be displayed depending on the model and other settings. M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M Program Pattern M M M M M M M M M M M M M M M M M M M M M M pmsk on 25 0 C 25 0 l.adj ins 0.0 inrt 1.000 c-p 8.0 c-i 233 c-d 40 M M M M M M M p 8.0 i 233 d 40 c-db 0.0 of-r 50.0 hys 1.0 chys 1.0 soak 1 wt-b off mv-s 0.0 pmov 0 psel cwf u-no 1 bps 9.6 len 7 sbit 2 prty even sdwt 20 M Write Mode maxu 0 area 0 adrh 0 adrl 0 rwat 1000 unit 0 up 1 1 up13 0 dn 1 31 dn13 75 copy off oapt 0 icpt 1 wtpt off pfpt off M M prlp 0 mv-e 0.0 sprl same M sprt off w1on w2on w3on w4of w5on w6on w7on w8on w1of w2of w3of w4on w5of w6of w7of w8of plcm 0 ol-h 100.0 ol-l 0.0 M sqrp 0.0 at off cmwt off ct1 0.0 M hb1 0.0 lcr1 0.0 hs1 50.0 sp-0 0 sp-1 0 sp-2 0 sp-3 0 sp-4 0 sp-5 0 sp-6 0 sp-7 0 M sp-3 0 r-s run in-t 5 in-h 100 in-l 0 dp 0 d-u c sl-h 1300 sl-l -200 cntl pid s-hc stnd ptrn off al-1 0 al1h 0 al1l 0 al-2 0 al2h 0 al2l 0 al-4 0 al4h 0 al4l 0 M M M al-3 0 al3h 0 al3l 0 o 0.0 c-o 0.0 25 0 a-m m-sp 0 sp-m 0 ct1 0.0 lcr1 0.0 prst rset M sktr 0 M orl 0.0 233 d-i Disturbance Integral Time M 40 d-d Disturbance Derivative Time ramm bkup * Press the M Key for at least one second to move to the previous parameter in the current setting level. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Automatic Filter Adjustment 0.6 w-dl 1.4 w-il off w-ht off a-ud 0.0 inf off fa Input Digital Filter PID Update (Adaptive Control) Water-cooling Output Adjustment Water-cooling Proportional Band Increase Threshold Water-cooling Proportional Band Decrease Threshold 8.0 d-p 40 sp-d 233 sp-i 8.0 sp-p SP Response Proportional Band SP Response Integral Time SP Response Derivative Time 0 sp-n SP Response Coefficient Number Disturbance Proportional Band 0 m-of 0 m-on 0.0 m-mv 0.0 m-pv off adpt Adaptive Control Model Creation PV Amplitude Model Creation MV Amplitude Model Creation ON Time Model Creation OFF Time *1 *1 Starting in Manual Mode. Starting in Automatic Mode. PID Control only PV/MV Press the O Key less than 1 s. Press the O and M Keys for at least 3 s. Press the O and M Keys for at least 1 s. Press the O Key less than 1 s. Press the O Key for at least 1 s. Press the O Key for less than 1 s. Press the O Key for at least 3 s. Other than the Auto/Manual Switch display Press the S Key*2 Press the S Key for at least 1 s. Press the O Key or the S Key for at least 1 s. *1. When the PF Setting parameter is set to A-M. *2. When the PF Setting parameter is set to PFDP. Press the S Key*2 Displayed only for models with communications. Changes are effective after cycling power or after a software reset. * Used with programless communications Power ON Adjustment Level Press the O Key less than 1 s. Manual Control Level Adjustment Level Display Displayed only once when entering adjustment level. AT Execute/Cancel Communications Writing Heater Current 1 Value Monitor Heater Burnout Detection 1 Leakage Current 1 Monitor HS Alarm 1 SP 4 SP 5 SP 6 SP 7 SP 0 SP 1 SP 2 SP 3 Proportional Band (Cooling) Integral Time (Cooling) Derivative Time (Cooling) Process Value Input Shift Process Value Slope Coefficient Proportional Band Integral Time Derivative Time Dead Band SP Ramp Fall Value Manual Reset Value Hysteresis (Heating) Hysteresis (Cooling) Soak Time Wait Band MV at Stop MV at PV Error SP Ramp Set Value MV Upper Limit MV Lower Limit MV Change Rate Limit Work Bit 1 ON Delay Work Bit 2 ON Delay Work Bit 3 ON Delay Work Bit 4 OFF Delay Work Bit 5 ON Delay Work Bit 6 ON Delay Work Bit 7 ON Delay Work Bit 8 ON Delay Work Bit 1 OFF Delay Work Bit 2 OFF Delay Work Bit 3 OFF Delay Work Bit 4 ON Delay Work Bit 5 OFF Delay Work Bit 6 OFF Delay Work Bit 7 OFF Delay Work Bit 8 OFF Delay Extraction of Square Root Low-cut Point Press the O Key for at least 3 s. Process Value/ Set Point 1 Process Value/ Set Point 2 Auto/Manual Switch Multi-SP Set Point Selection Set Point During SP Ramp Heater Current 1 Value Monitor Leakage Current 1 Monitor Program Start Soak Time Remain RUN/STOP Operation Level Communications Monitor Initial Setting Level Alarm Value 1 Alarm Value Upper Limit 1 Alarm Value Lower Limit 1 Alarm Value 2 Alarm Value Upper Limit 2 Alarm Value Lower Limit 2 Alarm Value 3 Alarm Value Upper Limit 3 Alarm Value Lower Limit 3 MV Monitor (Heating) MV Monitor (Cooling) Alarm Value Upper Limit 4 Alarm Value Lower Limit 4 Alarm Value 4 Protect Level Communications Setting Level Move to Protect Level : Displayed only when a password is set. Restricts moving to protect level. Operation/Adjustment Protect Initial Setting/Communications Protect Setting Change Protect Password to Move to Protect Level PF Key Protect Parameter Mask Enable Protocol Setting: Switches between CompoWay/F and Modbus. Communications Unit No. Communications Baud Rate Communications Data Length Communications Stop Bits Communications Parity Send Data Wait Time Input Type Scaling Upper Limit Scaling Lower Limit Decimal Point Temperature Unit °C, °F SP Upper Limit SP Lower Limit PID ON/OFF Standard or Heating/Cooling Highest Communications Unit No. The time taken to move to the protect level can be adjusted by changing the "Move to protect level time" setting. Area First Address Upper Word First Address Lower Word Receive Data Wait Time Communications Node Number Upload Setting 1 Upload Setting 13 Download Setting 1 Download Setting 13 Copy MASK MASK MASK MASK MASK This mark indicates masked parameters. Disable the mask to display the parameter. Refer to 5-12 Hiding Parameters in the E5 D Digital Temperature Controller User’s Manual (Cat. No. H224). MASK |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |