30 / 54 page ![]() MCP9804 DS22203A-page 30 © 2009 Microchip Technology Inc. 5.2 SENSOR FEATURE DESCRIPTION 5.2.1 SHUTDOWN MODE Shutdown mode disables all power-consuming activities (including temperature sampling operations) while leaving the serial interface active. This mode is selected by setting bit 8 of CONFIG to ‘1’. In this mode, the device consumes ISHDN. It remains in this mode until bit 8 is cleared ‘0’ to enable Continuous Conversion mode, or until power is recycled. The Shutdown bit (bit 8) cannot be set to ‘1’ while bits 6 and 7 of CONFIG (Lock bits) are set to ‘1’. However, it can be cleared ‘0’ or returned to Continuous Conversion while locked. In Shutdown mode, all registers can be read or written. However, the serial bus activity increases the shutdown current. In addition, if the device is in shutdown while the Alert pin is asserted, the device will retain the active state during shutdown. This increases the shutdown current due to the additional Alert output current. 5.2.2 TEMPERATURE HYSTERESIS (THYST) A hysteresis of 0°C, 1.5°C, 3°C or 6°C can be selected for the TUPPER, TLOWER and TCRIT temperate boundaries using bits 10 and 9 of CONFIG. The hysteresis applies for decreasing temperature only (hot to cold), or as temperature drifts below the specified limit. The hysteresis bits can not be changed if either of the lock bits, bits 6 and 7 of CONFIG, are set to ‘1’. The TUPPER, TLOWER and TCRIT boundary conditions are described graphically in Figure 5-11. 5.2.3 ALERT OUTPUT CONFIGURATION The Alert output can be enabled using bit 3 of CONFIG (Alert output control bit) and can be configured as either a comparator output or as Interrupt Output mode using bit 0 of CONFIG (Alert mode). The polarity can also be specified as an active-high or active-low using bit 1 of CONFIG (Alert polarity). This is an open drain output and requires a pull-up resistor. When the ambient temperature increases above the critical temperature limit, the Alert output is forced to a comparator output (regardless of bit 0 of CONFIG). When the temperature drifts below the critical temperature limit minus hysteresis, the Alert output automatically returns to the state specified by bit 0 of CONFIG. FIGURE 5-10: Active-Low Alert Output Configuration. The status of the Alert output can be read using bit 4 of CONFIG (Alert status). This bit can not be set to ‘1’ in shutdown mode. Bit 7 and 6 of the CONFIG register can be used to lock the TUPPER, TLOWER and TCRIT registers. The bits prevent false triggers at the Alert output due to an accidental rewrite to these registers. The Alert output can also be used as a critical temperature output using bit 2 of CONFIG (critical output only). When this feature is selected, the Alert output becomes a comparator output. In this mode, the interrupt output configuration (bit 0 of CONFIG) is ignored. 5.2.3.1 Comparator Mode Comparator mode is selected using bit 0 of CONFIG. In this mode, the Alert output is asserted as active-high or active-low using bit 1 of CONFIG. Figure 5-11 shows the conditions that toggle the Alert output. If the device enters Shutdown mode with asserted Alert output, the output remains asserted during Shutdown. The device must be operating in Continuous Conversion mode for tCONV; the TA vs. TUPPER, TLOWER and TCRIT boundary conditions need to be satisfied in order for the Alert output to deassert. Comparator mode is useful for thermostat-type applications, such as turning on a cooling fan or triggering a system shutdown when the temperature exceeds a safe operating range. 5.2.3.2 Interrupt Mode In the Interrupt mode, the Alert output is asserted as active-high or active-low (depending on the polarity configuration) when TA drifts above or below TUPPER and TLOWER limits. The output is deasserted by setting bit 5 (Interrupt Clear) of CONFIG. Shutting down the device will not reset or deassert the Alert output. This mode can not be selected when the Alert output is used as critical temperature output only, using bit 2 of CONFIG. This mode is designed for interrupt driven microcontroller based systems. The microcontroller receiving the interrupt will have to acknowledge the interrupt by setting bit 5 of CONFIG register from the MCP9804. MCP9804 Alert Output RPU VDD |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |