95 / 160 page ![]() ST7625 Ver 1.6 95/160 2008/07 9.1.26 DutySet: Display Duty setting (B0H) Command A0 /RD /WR D7 D6 D5 D4 D3 D2 D1 D0 Hex DutySet 0 1 0 1 0 1 1 0 0 0 0 (B0h) Parameter 1 1 0 0 Du6 Du5 Du4 Du3 Du2 Du1 Du0 - NOTE: “-“ Don’t care Description This command is used to set display duty. Command set = display duty numbers - 1. Example: Duty Du6 Du5 Du4 Du3 Du2 Du1 Du0 Command set= Display duty numbers-1 Example: 1/96 duty 1 0 1 1 1 1 1 96-1=95 Restriction Display duty must > 4 (1/4 duty) Register Availability Status Availability Normal Mode On, Idle Mode Off, Sleep Out Yes Normal Mode On, Idle Mode On, Sleep Out Yes Partial Mode On, Idle Mode Off, Sleep Out Yes Partial Mode On, Idle Mode On, Sleep Out Yes Sleep In Yes Default Status Default Value (Du[6:0]) Power On Sequence 01011101b (5Fh) S/W Reset 01011101b (5Fh) H/W Reset 01011111b (5Fh) Flow Chart |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|