37 / 84 page ![]() Production Data WM9093 w PD, March 2012, Rev 4.2 37 CONTROL INTERFACE The WM9093 is controlled by writing to registers through a 2-wire serial control interface. Readback is available for all registers, including Chip ID and power management status. The WM9093 is a slave device on the control interface; SCL is a clock input, while SDA is a bi- directional data pin. To allow arbitration of multiple slaves (and/or multiple masters) on the same interface, the WM9093 transmits logic 1 by tri-stating the SDA pin, rather than pulling it high. An external pull-up resistor is required to pull the SDA line high so that the logic 1 can be recognised by the master. Note that the control interface can support I/O levels up to 2.7V. In order to allow many devices to share a single 2-wire control bus, every device on the bus has a unique 7-bit device ID (this is not the same as the 8-bit address of each register in the WM9093). The WM9093 device ID is 1101_1100 (DCh). The LSB of the device ID is the Read/Write bit; this bit is set to logic 1 for “Read” and logic 0 for “Write”. The WM9093 operates as a slave device only. The controller indicates the start of data transfer with a high to low transition on SDA while SCL remains high. This indicates that a device ID, register address and data will follow. All devices on the 2-wire bus respond to the start condition and shift in the next eight bits on SDA (7-bit device ID + Read/Write bit, MSB first). If the device ID received matches the device ID of the WM9093, then the WM9093 responds by pulling SDA low on the next clock pulse (ACK). If the device ID is not recognised or the R/W bit is ‘1’ when operating in write only mode, the WM9093 returns to the idle condition and waits for a new start condition and valid address. If the device ID matches the device ID of the WM9093, the data transfer continues as described below. The controller indicates the end of data transfer with a low to high transition on SDA while SCL remains high. After receiving a complete address and data sequence the WM9093 returns to the idle state and waits for another start condition. If a start or stop condition is detected out of sequence at any point during data transfer (i.e. SDA changes while SCL is high), the device returns to the idle condition. The WM9093 supports the following read and write operations: Single write Single read Multiple write using auto-increment Multiple read using auto-increment |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |