| データシートサーチシステム |
|
SCML20122R2MTF データシート(PDF) 5 Page - Socay Electornics Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
SCML20122R2MTF データシート(HTML) 5 Page - Socay Electornics Co., Ltd. |
|
5 / 5 page ![]() Multilayer Chip Inductor Revision February 12, 2014 5 / 5 @ SOCAY Electronics Co., Ltd. 2014 Specifications are subject to change without notice. Please refer to www.socay.com for current information. SCML Series SOCAY Electronics Co., Ltd. www.socay.com Test item Test condition Criteria Resistance to Solder Heat 1. Solder temperature : 260 ±5ºC 2. Flux : Rosin 3. DIP time : 10 ±1 sec 1. More than 95 % of terminal electrode should be covered with new solder 2. No mechanical damage 3. Induction value should be within ±10 % of the initial value Adhesive Test 1. Reflow temperature : 245 ºC It shall be Soldered on the substrate applying direction parallel to the substrate 2. Apply force(F) : 5 N 3. Test time : 10 sec 1. No mechanical damage 2. Soldering the products on PCB after the pulling test force > 5 N Steam Aging Test 1. Temperature : 93 ºC 2. Test time : 8 hours 3. Solder temperature : 235 ±5ºC 4. Flux : Rosin 5. DIP time : 5 ±1 sec 1. More than 95 % of terminal electrode should be covered with new solder Temperature Cycle 1. Temperature : -40 ~ +85 ºC for 30 minutes each 2. Cycle : 100 cycles 3. Measurement : At ambient temperature 24 hours after test completion 1. No mechanical damage 2. Induction value should be within ±20 % of the initial value Operational Life 1. Temperature : 85 ºC±5ºC 2. Test time : 1000 hours 3. Apply current : full rated current 4. Measurement : At ambient temperature 24 hours after test completion 1. No mechanical damage 2. Induction value should be within ±10 % of the initial value Biased Humidity 1. Temperature : 40 ºC±2ºC 2. Humidity : 90 ~ 95 % RH 3. Apply current : full rated current 4. Test time : 1000 hours 5. Measurement : At ambient temperature 24 hours after test completion 1. No mechanical damage 2. Induction value should be within ±20 % of the initial value Rated Current At ambient temperature & humidity Test time: 5 minutes (under full rated current) MIP product surface temp: below room temperature plus 40 ºC Reliability and Test Condition |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |