| データシートサーチシステム |
|
L6207 データシート(PDF) 21 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6207 データシート(HTML) 21 Page - STMicroelectronics |
|
21 / 53 page ![]() 21/53 AN1762 APPLICATION NOTE Figure 21. Typical disable and delay time as a function of CEN, for several values of REN. 3.13 Adjusting the Over Current Detection trip point (L6206 ONLY) The L6206 allows the user to set the Over Current Detection threshold separately for the two full bridges con- necting two resistors (RCL) to pins PROGCLA and PROGCLB. The OCD threshold (ISOVER) follows the equa- tions: –ISOVER = 5.6A ±30% at -25 °C < Tj < 125 °C if RCL = 0 Ω (PROGCL connected to GND) –ISOVER = ±10% at -25 °C < Tj < 125 °C if 5K Ω < RCL < 40k Ω Figure 22 shows the OCD threshold versus RCL value in the range from 5kΩ to 40kΩ. 11 0 1 0 0 0. 1 1 10 C EN [ nF] 11 0 1 0 0 1 10 10 0 1 . 10 3 C EN [ nF] R EN = 220 k Ω R EN = 100 k Ω R EN = 47 k Ω R EN = 33 k Ω R EN = 10 k Ω 22100 R CL ---------------- |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|