11 / 29 page ![]() AN3093 Efficiency and no-load measurements Doc ID16539 Rev 1 11/29 3 Efficiency and no-load measurements The efficiency of the converter has been measured in different load and line voltage conditions. According to the Energy Star average active mode testing efficiency method, the efficiency measurements have been performed at 25%, 50% and 75% and 100% of the rated output power, at both 115 VAC and 230 VAC. Table 4 and Table 5 show the results. Table 4. Efficiency at 115 VAC Load [%] IOUT [A] VOUT [V] POUT [W] PIN [W] Efficiency [%] 25 0.25 4.97 1.243 1.643 75.62 50 0.5 4.97 2.485 3.156 78.74 75 0.75 4.97 3.728 4.72 78.97 100 1 4.98 4.980 6.4 77.81 Average efficiency 77.79 Table 5. Efficiency at 230 VAC Load [%] IOUT [A] VOUT [V] POUT [W] PIN [W] Efficiency [%] 25 0.25 4.98 1.245 1.88 66.22 50 0.5 4.97 2.485 3.349 74.18 75 0.75 4.98 3.735 4.838 77.22 100 1 4.99 4.99 6.326 78.88 Average efficiency 74.12 |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|