Back Button AN3322 Datasheet HTML 26Page - STMicroelectronics AN3322 Datasheet HTML 27Page - STMicroelectronics AN3322 Datasheet HTML 28Page - STMicroelectronics AN3322 Datasheet HTML 29Page - STMicroelectronics AN3322 Datasheet HTML 30Page - STMicroelectronics AN3322 Datasheet HTML 31Page - STMicroelectronics AN3322 Datasheet HTML 32Page - STMicroelectronics AN3322 Datasheet HTML 33Page - STMicroelectronics AN3322 Datasheet HTML 34Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 30 / 38 page
background image
Computational issues and compensation algorithms
AN3322
30/38
DocID18304 Rev 1
Since the voltage signal with very low amplitude can lead to incorrect zero crossing
detection, the zero crossing detection is not performed on the voltage signal with an
amplitude lower that 50 V. The measured frequency and locking to the zero crossing is not
updated in this case.
2.7
Phase shift correction
This section describes how to deal with phase shift in the analog circuitry of the STM32
power meter. The evaluation of the error caused by phase shift and the levels of its
correction is computed in Section 2.7.1, Section 2.7.2, and Section 2.7.3.
2.7.1
Phase shift measured for the STM32 meter
The phase shift that needs to be compensated was measured directly in the STM32 meter.
These values help to set the limits and resolution of the phase shift compensation method.
Figure 18. Zero crossing for green - U, blue - ILG, red- IHG
Figure 18 shows that there is a delay between voltage U and currents ILG and IHG. This
delay between U and ILG or between U and IHG is in the same range for both ranges and it
is 5 - 8 µs. This delay is mainly caused by the capacitance and inductance in the signal path
of the input voltage divider (see Section 2.10).
2.7.2
Phase shift correction - error evaluation
The phase shift between voltage and current is also caused by non-simultaneous sampling
of these values, see Section 1.9.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com