21 / 74 page ![]() DRDY_N I-to-V Conversion CONVERT_END CONVERT_START DRDY_S DRDY_H V-to-I Conversion DEVICE_STATUS[DRDY] S R Q Q SET CLR bq76PL536A www.ti.com SLUSAD3B – JUNE 2011 – REVISED JANUARY 2016 Feature Description (continued) 7.3.1.7.2 Data Ready The bq76PL536A signals that data is ready when the last conversion data has been stored to the associated data result register by asserting the DRDY_S pin (DRDY_H if HOST = 0) if the DRDY_N pin is also asserted (Figure 15). DRDY_S (DRDY_H) signals are cleared on the next conversion start. Figure 15. Data-Ready Logic 7.3.1.7.3 ADC Channel Selection The ADC_CONTROL register can be configured as follows: Table 1. ADC_CONTROL Register Configuration MEASUREMENT ADC_CONTROL VCELL1 CELL_SEL = 0x00 VCELL1, VCELL2 CELL_SEL = 0x01 VCELL1, VCELL2, VCELL3 CELL_SEL = 0x02 VCELL1, VCELL2, VCELL3, VCELL4 CELL_SEL = 0x03 VCELL1, VCELL2, VCELL3, VCELL4, VCELL5 CELL_SEL = 0x04 VCELL1, VCELL2, VCELL3, VCELL4, VCELL5, VCELL6 CELL_SEL = 0x05 External thermistor input 1 TS1 = 1 External thermistor input 2 TS2 = 1 General-purpose analog input GPAI = 1 7.3.1.7.4 Conversion Time Control The ADC conversion time is fixed at approximately 6 µs per converted channel, plus 6 µs overhead at the start of the conversion. Total conversion time (µs) is approximately 6 × num_channels + 6. 7.3.1.7.5 Automatic Versus Manual Control The ADC_CONTROL[ADC_ON] bit controls powering up the ADC section and the main bandgap reference. If the bit is set to 1, the internal circuits are powered on, and current consumption by the part increases. Conversions begin immediately on command. The host CPU should wait >500 µs before initiating the first conversion after setting this bit. If the ADC_ON bit is false, an additional 500 µs is required to stabilize the reference before conversions begin. If the sampling interval (time between conversions) used is less than approximately 10 ms, manual mode should be selected to avoid shifting the voltage reference, leading to inaccuracy in the measurements. Copyright © 2011–2016, Texas Instruments Incorporated Submit Documentation Feedback 21 Product Folder Links: bq76PL536A |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |