4 / 20 page ![]() L-8 Switch mode Power Supply S82K 3- to 240-W models without PFC Note: 1. Defined with a 100% load and the rated input voltage (100 or 200 VAC). 2. The output specification is defined at the power supply output terminals. 3. The settings for the output voltage must be within the following range: +V: ±1% of the rated value −V: ±5% of the rated value 4. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the protection function will operate at a current of 95% to 160% of the rated load current. 5. When the ambient temperature exceeds 25 °C, the protection function will operate at a current of 92% to 111% of the rated load current. 6. Circuit-breaker type. To reset, turn the input power supply OFF, then after 1 min has elapsed, turn the input power supply ON again. 7. Parallel operation is set with the Parallel/Single Operation Selector Switch. (This setting is not required for S82K-10024 models.) Item Single output Dual outputs Single output 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Output (see note 2) Voltage adjustment range ±10% (V.ADJ) Not possi- ble (see note 3) ±10% (V.ADJ); −10% to 15% for S82K-03012/-03024/-05024 Ripple (see note 1) 2% (p-p) max. Input variation influence 0.5% max. (at 85 to 264 VAC input, 100% load) 0.5% max. (at 85 to 132 VAC/170 to 264 VAC input, 100% load) 0.5% max. (at 85 to 132 VAC/ 170 to 253 VAC input, 100% load) Load variation influence 1.5% max. (0 to 100% load) +V: 1.5% max. −V: 3% max. (0 to 100% load) 1.5% max. (0 to 100% load) 1.5% max. (10 to 100% load) Temperature variation influence (see note 1) 0.05%/ °C max. Start up time 100 ms max. (up to 90% of output voltage at rated input and output) 200 ms max. 300 ms max. Hold time (see note 1) 20 ms min. Additional function Overload protection 105% to 160% of rated load current, inverted L drop, automatic reset (see note 4) 105% to 250% of rated load current, in- verted L drop, auto- matic reset 105% to 160% of rated load cur- rent, inverted L drop, automatic reset (30-W, 50-W models: inverted L drop, intermittent, automatic re- set) 101% to 111% of rated load current, in- verted L drop, auto- matic re- set (see note 5) 105% to 160% of rated load current, inverted L drop, automatic reset Overvoltage protection (see note 6) No S82K- 24024T model only Undervoltage alarm indicator (DC LOW indicator) Yes (color: red) S82K- 24024T model only Undervoltage alarm output (DC LOW output) No Yes S82K- 24024T model only Parallel operation Impossible Possible (2 units max.) (see note 7) |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |