13 / 20 page ![]() Switch mode Power Supply S82K L-17 I Overload Protection The Power Supply is provided with an overload protection function that protects the load and the power supply from possible damage by overcur- rent. When the output current rises above a set value (refer to the table below), the protection function is triggered, decreasing the output voltage. When the output current falls within the rated range, the overload protection function is automatically cleared. Note: 1. When using the 7.5-W single-output models within the input voltage range between 90 and 110 VDC, the overload protection function will operate at currents from 95% to 160% of the rated load current. 2. When using the 90-W model at an ambient temperature exceeding 25 °C, the overload protection function will operate at currents from 92% to 111% of the rated load current. 3. When using the 100-W model with PFC in parallel operation, the overload protection function will operate at currents from 3.78 to 4.2 A. 65 70 90 240-W Model Parallel-Unit Operation Note: 100-VAC input: 85 to 132 VAC Ambient temperature ( °C) Ambient temperature ( °C) Single-Unit Operation Installation A Installation A 90-W Models Ambient temperature ( °C) Installation A Installation B 240-W Model Single-Unit Operation Note: 100-VAC input: 85 to 132 VAC S82K-P09024: 85-VAC input S82K-P24024: 100-VAC input (see note) S82K-P24024: 100-VAC input (see note) (A) Standard (Vertical) Installation (B) Horizontal Installation Top Top S82K- @@ Note: The derating curve above can be ensured for the above two kinds of installations. (Not permitted for 240-W models.) Single output Dual outputs Single output 3 W 7.5 W 7.5 W 15 W 30 W 50 W 90 W 100 W 240 W Set value 105% to 160% of rated load current (see note 1) 105% to 250% of rat- ed load cur- rent 105% to 160% of rated load current 101% to 111% of rat- ed load cur- rent (see notes 2 and 3) 105% to 160% of rated load current (see note 3) Operation Inverted L drop type, automatic reset Inverted L drop/intermittent operation type, automatic reset Inverted L drop type, automatic reset |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |