Back Button ADM1266ACPZ-R7 Datasheet HTML 30Page - Analog Devices ADM1266ACPZ-R7 Datasheet HTML 31Page - Analog Devices ADM1266ACPZ-R7 Datasheet HTML 32Page - Analog Devices ADM1266ACPZ-R7 Datasheet HTML 33Page - Analog Devices ADM1266ACPZ-R7 Datasheet HTML 34Page - Analog Devices ADM1266ACPZ-R7 Datasheet HTML 35Page - Analog Devices ADM1266ACPZ-R7 Datasheet HTML 36Page - Analog Devices ADM1266ACPZ-R7 Datasheet HTML 37Page - Analog Devices ADM1266ACPZ-R7 Datasheet HTML 38Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 34 / 62 page
background image
ADM1266
Data Sheet
Rev. A | Page 34 of 62
STANDARD PMBus COMMAND DESCRIPTIONS
All commands designated as Block WR/W consist of two writes and a read. A standard block write is performed to write to the
command, but the command must be written first before it can be read back.
STANDARD PMBus COMMANDS
Page
The page command provides the ability to configure, control, and monitor using only one physical address.
Table 12. Register 0x00—Page
Bits
Bit Name
Type
Description
[7:0]
PAGE
R/W
00000 = VH1.
00001 = VH2.
00010 = VH3.
00011 = VH4.
00100 = VP1.
00101 = VP2.
00110 = VP3.
00111 = VP4.
01000 = VP5.
01001 = VP6.
01010 = VP7.
01011 = VP8.
01100 = VP9.
01101 = VP10.
01110 = VP11.
01111 = VP12.
10000 = VP13.
Setting the page to 0xFF means that all following commands are to be applied to all inputs.
Operation
The operation command turns the closed-loop margining on and off, and determines which voltage to margin to.
Table 13. Register 0x01—Operation
Bits
Bit Name
R/W
Description
[7:6]
MARGIN_EN
R/W
01 is soft off, 10 is margin on, and others are reserved.
[5:4]
MARGIN_VOLTAGE
R/W
00 is VOUT_COMMAND (closed-loop servo to the voltage set in VOUT_COMMAND), 01 is margin
low, 10 is margin high, and others are reserved.
[3:2]
Fault
R/W
01 is ignore fault and others are reserved.
[1:0]
Reserved
R
Reserved.
CLEAR_FAULTS
The CLEAR_FAULTS command is a send byte, with no data. This command clears all fault bits in all PMBus status registers simultaneously.
Table 14. Register 0x03—CLEAR_FAULTS
Bits
Bit Name
Type
Description
Not Applicable
CLEAR_FAULTS
Send
Clears all bits in the PMBus status registers (Register 0x78 to Register 0x7A) simultaneously.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com