28 / 60 page ![]() 28 Am79C874 P R E L I M INARY PHY CONTROL AND MANAGEMENT BLOCK (PCM BLOCK) Register Administration for 100BASE-X PHY Device The management interface specified in Clause 22 of the IEEE 802.3u standard provides for a simple two wire, serial interface to connect a management entity and a managed PHY for the purpose of controlling the PHY and gathering status information. The two lines are Management Data Input/Output (MDIO), and Man- agement Data Clock (MDC). A station management entity which is attached to multiple PHY entities must have prior knowledge of the appropriate PHY address for each PHY entity. Description of the Methodology The management interface physically transports man- agement information across the MII. The information is encapsulated in a frame format as specified in Clause 22 of IEEE 802.3u draft standard and is shown in Table 6. Table 6. Clause 22 Management Frame Format The PHYAD field, which is five bits wide, allows 32 unique PHY addresses. The managed PHY layer de- vice that is connected to a station management entity via the MII interface has to respond to transactions addressed to the PHY address. A station management entity attached to multiple PHYs, such as in a managed 802.3 Repeater or Ethernet switch, is required to have prior knowledge of the appropriate PHY address. See Table 7 and Figure 7. Table 7. PHY Address Setting Frame Structure Figure 7. PHY Management Read and Write Operations PRE ST OP PHYAD REGADD TA DATA IDLE READ 1.1 01 10 AAAAA RRRRR Z0 D...........D Z WRITE 1.1 01 01 AAAAA RRRRR 10 D...........D Z PRE ST OP PHYAD REGADD TA DATA IDLE READ 1.1 01 10 00000 RRRRR Z0 XXXXXXXXXPPAAAAA Z WRITE 1.1 01 01 00000 RRRRR 10 XXXXXXXXXPPAAAAA Z Idle Start Opcode (Read) PHY Address 16h, Port 2 Register Address MII Status, 1h TA Register Data Idle z z z MDC MDIO (PHY) MDIO (STA) z z 0 1 1 0 1 0 1 1 0 0 0 0 0 1 0 0 1 1 0 0 00 010 0 0 0 0 1 0 z z Read Operation Idle Start Opcode (Write) PHY Address 16h, Port 2 Register Address MII Control, 0h TA Register Data Idle z z MDC MDIO (STA) z 01 01 1 0 1 1 00 0 0 0 0 1 0 0 1 1 0 0 0 1 0 0 0 0 0 0 0 0 0 z Write Operation 22235I-9 |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |