14 / 24 page ![]() LTM4619 14 4619f APPLICATIONS INFORMATION INTVCC and EXTVCC The INTVCC is the internal 5V regulator that powers the LTM4619 internal circuitry and drives the power MOSFETs. The input voltage of the LTM4619 must be 6V or above for the INTVCC to regulate to the proper 5V level due to the internal LDO dropout from the input voltage. For ap- plications that need to operate below 6V input, then the input voltage can be connected directly to the EXTVCC pin to bypass the LDO dropout concern, or an external 5V supply can be used to power the EXTVCC pin when the input voltage is at high end of the supply range to reduce power dissipation in the module. For example the dropout voltage for 24V input would be 24V – 5V = 19V. This 19V headroom then multiplied by the power MOSFET drive current of ~15mA would equal ~0.3W additional power dissipation. So utilizing an external 5V supply on the EXTVCC would improve design efficiency and reduce device temperature rise. Slope Compensation The module has already been internally compensated for all output voltages. The Linear Technology μModule Power Design Tool will be provided for control loop op- timization. Burst Mode Operation and Pulse-Skipping Mode The LTM4619 regulator can be placed into high efficiency power saving modes at light load condition to conserve power. The Burst Mode operation can be selected by float- ing the MODE/PLLIN pin, and pulse-skipping mode can be selected by pulling the MODE/PLLIN pin to INTVCC. Burst Mode operation offers the best efficiency at light load, but output ripple will be higher and lower frequency ranges are capable which can interfere with some systems. Pulse-skipping mode efficiency is not as good as Burst Mode operation, but this mode only skips pulses to save efficiency and maintains a lower output ripple and a higher switching frequency. Burst Mode operation and pulse-skip- ping mode efficiencies can be reviewed in graph supplied in the Typical Performance Characteristics section. Fault Conditions: Current Limit and Overcurrent Foldback The LTM4619 has a current mode controller, which inher- ently limits the cycle-by-cycle inductor current not only in steady-state operation, but also in transient. To further limit current in the event of an overload condi- tion, the LTM4619 provides foldback current limiting. If the output voltage falls by more than 50%, then the maximum output current is progressively lowered to one-third of its full current limit value. Foldback current limiting is disabled during the soft-start and tracking up. Thermal Considerations and Output Current Derating In different applications, the LTM4619 operates in a variety of thermal environments. The maximum output current is limited by the environmental thermal condition. Sufficient cooling should be provided to ensure reliable operation. When the cooling is limited, proper output current derat- ing is necessary, considering the ambient temperature, airflow, input/output conditions, and the need for increased reliability. Two outputs of LTM4619 are paralleled to get high output current for derating curve tests. The power loss curves in Figures 7 and 8 can be used in coordination with the load current derating curves in Figures 9 to 16 for calculating an approximate θJA for the module with various cooling methods. Application Note 103 provides a detailed ex- planation of the analysis for the thermal models and the derating curves. Tables 2 and 3 provide a summary of the equivalent θJA for the noted conditions. These equivalent θJA parameters are correlated to the measured values, and are improved with airflow. The junction temperature is maintained at 125°C or below for the derating curves. Safety Considerations The LTM4619 modules do not provide isolation from VIN to VOUT. There is no internal fuse. If required, a slow blow fuse with a rating twice the maximum input current needs to be provided to protect each unit from catastrophic failure. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |