| データシートサーチシステム |
|
TLE8201R データシート(PDF) 19 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE8201R データシート(HTML) 19 Page - Infineon Technologies AG |
|
19 / 45 page ![]() TLE 8201R Data Sheet Rev. 2.0 19 2006-06-07 Table 4 Status bit definitions Status Bit Definition LSxOvL Low-Side switch Over Load. Set to HIGH if low-side switch no. x is shut down due to overcurrent or over temperature HSxOvL High-Side switch Over Load. Set to HIGH if high-side switch no. x is shut down due to overcurrent or over temperature LSxOpL Low-Side switch open load. Set to HIGH if open load (undercurrent) is detected in low-side switch x HSxOpL High-Side switch Open Load. Set to HIGH if open load is detected in high- side switch x PSF Power Supply Fail. Set to HIGH if the Voltage at the Vs pin is below the Vs under-voltage threshold or above the Vs over-voltage threshold TSD one or more powerstages are shut down due to over temperature TW one or more powerstages have reached the warning temperature EF_xy Error Flag for StatReg xy. Set to HIGH if any bit is set to HIGH StatReg xy n.c. not connected. These bits may be used for test-mode purposes. They are set to fixed LOW in normal operation |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|