| データシートサーチシステム |
|
X24026 データシート(PDF) 6 Page - Xicor Inc. |
|
|
|||||||||||||||||||||||||||||
X24026 データシート(HTML) 6 Page - Xicor Inc. |
|
6 / 15 page ![]() X24026 6 Page Write The X24026 is capable of a four byte page write opera- tion. It is initiated in the same manner as the byte write operation, but instead of terminating the write cycle after the first data word is transferred, the master can transmit up to three more words. After the receipt of each word, the X24026 will respond with an acknowledge. After the receipt of each word, the two low order address bits are internally incremented by one. The high order six bits of the address remain constant. If the master should transmit more than four words prior to generating the stop condition, the address counter will “roll over” and the previously written data will be overwritten. As with the byte write operation, all inputs are disabled until comple- tion of the internal write cycle. Refer to Figure 6 for the address, acknowledge and data transfer sequence. Acknowledge Polling The disabling of the inputs, during the internal write oper- ation, can be used to take advantage of the typical 5 ms write cycle time. Once the stop condition is issued to indi- cate the end of the host’s write operation the X24026 ini- tiates the internal write cycle. ACK polling can be initiated immediately. This involves issuing the start condition fol- lowed by the slave address for a write operation. If the X24026 is still busy with the write operation no ACK will be returned. If the X24026 has completed the write oper- ation an ACK will be returned and the master can then proceed with the next read or write operation. READ OPERATIONS Read operations are initiated in the same manner as write operations with the exception that the R/W bit of the slave address is set to a one. There are three basic read operations: current address read, random read and sequential read. It should be noted that the ninth clock cycle of the read operation is not a “don’t care.” To terminate a read opera- tion, the master must either issue a stop condition during the ninth cycle or hold SDA HIGH during the ninth clock cycle and then issue a stop condition. Flow 1. ACK Polling Sequence 7020 FRM 09 WRITE OPERATION COMPLETED ENTER ACK POLLING ISSUE START ISSUE SLAVE_ ADDRESS AND R/W = 0 ACK RETURNED? NEXT OPERATION A WRITE? ISSUE BYTE ADDRESS PROCEED ISSUE STOP NO YES YES PROCEED ISSUE STOP NO |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |