13 / 24 page ![]() AD7887 Rev. D | Page 13 of 24 POWER-DOWN OPTIONS The AD7887 provides flexible power management to allow the user to achieve the best power performance for a given throughput rate. The power management options are selected by programming the power management bits (that is, PM1 and PM0) in the control register. Table 6 summarizes the available options. When the power management bits are programmed for either of the auto power-down modes, the part enters power-down mode on the 16th rising SCLK edge after the falling edge of CS. The first falling SCLK edge after the CS falling edge causes the part to power up again. When the AD7887 is in Mode 1, that is, PM1 = PM0 = 0, the part enters shutdown on the rising edge of CS and power up from shutdown on the falling edge of CS. If CS is brought high during the conversion in this mode, the part immediately enters shutdown. Power-Up Times The AD7887 has an approximate 1 μs power-up time when powering up from standby or when using an external reference. When VDD is first connected the AD7887 powers up in Mode 1, that is, PM1 = PM0 = 0. The part is put into shutdown on the rising edge of CS in this mode. A subsequent power-up from shutdown takes approximately 5 μs. The AD7887 wake-up time is very short in the autostandby mode; therefore, it is possible to wake up the part and carry out a valid conversion in the same read/write operation. POWER VS. THROUGHPUT RATE By operating the AD7887 in autoshutdown mode, autostandby mode, or Mode 1, the average power consumption of the AD7887 decreases at lower throughput rates. Figure 15 shows how as the throughput rate is reduced, the device remains in its power-down state longer and the average power consumption over time drops accordingly. For example, if the AD7887 is operated in a continuous sampling mode with a throughput rate of 10 kSPS and a SCLK of 2 MHz (VDD = 5 V), PM1 = 1 and PM0 = 0, that is, the device is in auto- shutdown mode, and the on-chip reference is used, the power consumption is calculated as follows: The power dissipation during normal operation is 3.5 mW (VDD = 5 V). If the power-up time is 5 μs and the remaining conversion plus acquisition time is 15.5 tSCLK, that is, approximately 7.75 μs (see Figure 18), the AD7887 can be said to dissipate 3.5 mW for 12.75 μs during each conversion cycle. If the throughput rate is 10 kSPS, the cycle time is 100 μs and the average power dissipated during each cycle is (12.75/100) × (3.5 mW) = 446.25 μW. If VDD = 3 V, SCLK = 2 MHz, and the device is in autoshutdown mode using the on-chip reference, the power dissipation during normal operation is 2.1 mW. The AD7887 can now be said to dissipate 2.1 mW for 12.75 μs during each conversion cycle. With a throughput rate of 10 kSPS, the average power dissipated during each cycle is (12.75/100) × (2.1 mW) = 267.75 μW. Figure 15 shows the power vs. throughput rate for automatic shutdown with both 5 V and 3 V supplies. THROUGHPUT RATE (kSPS) 10 0 1 10 0.1 0.01 VDD = 5V SCLK = 2MHz VDD = 3V SCLK = 2MHz 20 50 40 30 Figure 15. Power vs. Throughput Rate MODES OF OPERATION The AD7887 has several modes of operation that are designed to provide flexible power management options. These options can be chosen to optimize the power dissipation/throughput rate ratio for differing application requirements. The modes of operation are controlled by the PM1 and PM0 bits of the control register, as previously outlined in Table 6. For read-only operation of the AD7887, the default mode of all 0s in the control register can be set up by tying the DIN line permanently low. Mode 1 (PM1 = 0, PM0 = 0) This mode allows the user to control the powering down of the part via the CS pin. Whenever CS is low, the AD7887 is fully powered up; whenever CS is high, the AD7887 is in full shutdown. When CS goes from high to low, all on-chip circuitry starts to power up. It takes approximately 5 μs for the AD7887 internal circuitry to be fully powered up. As a result, a conversion (or sample-and-hold acquisition) should not be initiated during this 5 μs. Figure 16 shows a general diagram of the operation of the AD7887 in this mode. The input signal is sampled on the second rising edge of SCLK following the CS falling edge. The user should ensure that 5 μs elapses between the falling edge of CS and the second rising edge of SCLK. In microcontroller applications, this is readily achievable by driving the CS input from one of the port lines and ensuring that the serial data read (from the microcontrollers serial port) is not initiated for 5 μs. In DSP applications, where CS is generally derived from the serial frame synchronization line, it is usually not possible to separate the CS falling edge and second SCLK rising edge by up to 5 μs without affecting the speed of the rest of the serial clock. Therefore, the user must write to the control register to exit this mode and (by writing PM1 = 0 and PM0 = 1) put the part into Mode 2, that is, normal mode. A second conversion needs to be initiated when the part is powered up to get a conversion result. The write operation that takes place in conjunction with this |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |