| データシートサーチシステム |
|
N5393D データシート(PDF) 22 Page - Keysight Technologies |
|
|
|||||||||||||||||||||||||||||
N5393D データシート(HTML) 22 Page - Keysight Technologies |
|
22 / 25 page ![]() 22 | Keysight | N5393D PCI Express® 3.0 (Gen3) Software for Infiniium Oscilloscopes - Data Sheet Ordering Information PCIe switch matrix support License type Infiniium Z-Series Infiniium S-Series Infiniium 90000 Series Fixed Factory-installed N5393D-7FP N5393E-7FP 1 Option 705 User-installed N5393D-7FP N5393E-7FP 1 N5393D-7NL Floating Transportable N5393D-7TP N5393E-7TP 1 N5393D-7TP Server-based N5435A-705 PCIe 3.0 BASE spec receiver test calibration License type Infiniium Z-Series Infiniium S-Series Infiniium 90000 Series Fixed Factory-installed N5393D-4FP — — User-installed N5393D-4FP — N5393D-4NL Floating Transportable N5393D-4TP — N5393D-4TP Server-based — PCIe 3.x transmitter testing License type Infiniium Z-Series Infiniium S-Series Infiniium 90000 Series Fixed Factory-installed N5393D-1FP — Option 044 User-installed N5393D-1FP — N5393D-1NL Floating Transportable N5393D-1TP — N5393D-1TP Server-based N5435A-040 Upgrade to PCIe 3.0 transmitter testing License type Infiniium Z-Series Infiniium S-Series Infiniium 90000 Series Fixed Factory-installed — — — User-installed N5393D-2FP — N5393D-2NL Floating Transportable — — — Server-based — PCI Express 1.x and 2.x transmitter testing License type Infiniium Z-Series Infiniium S-Series Infiniium 90000 Series Fixed Factory-installed N5393D-3FP N5393E-3FP 1 Option 022 User-installed N5393D-3FP N5393E-3FP 1 N5393D-3NL Floating Transportable N5393D-3TP N5393E-3TP 1 N5393D-3TP Server-based N5435A-009 1. The S-Series oscilloscope is limited to a maximum bandwidth of 8 GHz which is sufficient bandwidth only for 2.5 GT/s (PCIe 1.x) transmitter measurements. Transmitter measurements for 5GT/s (PCIe 2.x) and 8 GTs (PCIe 3.x) require a minimum scope bandwidth of 12 GHz; however, PCIe 2.x clock phase jitter measurements can be made with the S-Series oscilloscope and are thus enabled with this license. 5GT/s transmitter measurements are not enabled on the S-Series oscilloscope as a higher minimum bandwidth is required. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |