M7F データシート(PDF) 12 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
M7F データシート(HTML) 12 Page - Omron Electronics LLC |
|
12 / 16 page ![]() M7F 12 Operation ■ Operation Timing (Input Signal Timing) Dynamic Input Method (M7F- @D@@@) ■ Operation Chart Dynamic Input Method (M7F- @D@@@) The following example shows the relationship between each input terminal and the display condition. (Example: 5-digit) ts tw th Data latch Data input signals A to D Strobe input (S0 to S4) Data latch Data read H L Pulse duration (tw) 1.5 ms Hold time (th) 0.75 ms Setup time (ts) 2.25 ms Display condition H L H L H L H L H L Data contents 5 3 1 8 9 A numeric value is displayed one digit at a time via data signals A to D. Data input signals (A to D) 1st digit (S0) 2nd digit (S1) 3rd digit (S2) 4th digit (S3) 5th digit (S4) 1st-digit display change 2nd-digit display change 3rd-digit display change 4th-digit display change 5th-digit display change Data read Data latch Data latch Data read Data latch Data latch Data read Data latch Data latch Data read Data latch Data latch Data read Data latch Data input signals Strobe input signals |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |