| データシートサーチシステム |
|
RT9758 データシート(PDF) 46 Page - Richtek Technology Corporation |
|
|
|||||||||||||||||||||||||||||
RT9758 データシート(HTML) 46 Page - Richtek Technology Corporation |
|
46 / 61 page ![]() RT9758 Copyright © 2023 Richtek Technology Corporation. All rights reserved. is a registered trademark of Richtek Technology Corporation. www.richtek.com DS9758-03 May 2023 46 Auto Transition Function Feature (AT_Function) For more flexible mode change application between bypass mode and DIV2 mode, the auto transition function (AT_Function) is established in the RT9758 to make converter mode change automatically by adjusting VBUS voltage. In register map, the AT_FUNCTION_EN bit is used to enable this function and the AT_FUNCTION bit is used to set the threshold of mode transition. When the AT_Function is active in bypass mode, if VBUS is higher than AT_Function threshold in tAT_FUNCTION_DEG time, the device will stop charging, set OPERATION_MODE_ SELECTION bit to 1 and then start DIV2 charging process if the start-up conditions are met. In another case, if VBUS is lower than AT_Function threshold when the device operates in DIV2 mode, it will stop charging, set OPERATION_MODE_ SELECTION bit to 0 and then start bypass charging process if the start-up conditions are met. The Figure 8 is recommended operation flow for using auto transition function, user should follow step 1-4 to use auto transition function. Especially, if user desires device be transited from bypass mode to DIV mode by using AT_Function, be sure to enable VOUT_PD bit to 1 before increase VBUS voltage. 1. Set AT_FUNCTION threshold level 2. Set AT_FUNCTION_EN = 1 to enable AT_Function Set VOUT_PD = 1 to enable VOUT pull down resistor 3. Increase VBUS higher than AT_Function threshold and over 10msec deglitch time Device stop charging & set OPERATION_MODE_SELECTION = 1 automatically Start DIV2 charging process when VBUS_INSERT = 1 & VBUS_LOW_ERR = 0 Device operates in DIV2 mode Device operates in bypass mode 1. Set AT_FUNCTION threshold level 2. Set AT_FUNCTION_EN = 1 to enable AT_Function 3. Decrease VBUS lower than AT_Function threshold and over 10msec deglitch time Device stop charging & set OPERATION_MODE_SELECTION = 0 automatically Start bypass charging process when VBUS_INSERT = 1 & VBUS_LOW_ERR = 0 Device operates in DIV2 mode Device operates in bypass mode 4. Set AT_FUNCTION_EN = 0 to disable AT_Function 4. Set AT_FUNCTION_EN = 0 to disable AT_Function Figure 8. Operation Flow for Using Auto Transition Function |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |