| データシートサーチシステム |
|
ADT7481ARMZ-R7 データシート(PDF) 9 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADT7481ARMZ-R7 データシート(HTML) 9 Page - ON Semiconductor |
|
9 / 20 page ![]() ADT7481 http://onsemi.com 9 Registers The registers in the ADT7481 are eight bits wide. These registers are used to store the results of remote and local temperature measurements, high and low temperature limits, and to configure and control the device. A description of these registers follows. Address Pointer Register The address pointer register does not have, nor does it require, an address because the first byte of every write operation is automatically written to this register. The data in this first byte always contains the address of another register on the ADT7481, which is stored in the address pointer register. It is to this register address that the second byte of a write operation is written to, or to which a subsequent read operation is performed. The power−on default value of the address pointer register is 0x00, so if a read operation is performed immediately after power−on, without first writing to the address pointer, the value of the local temperature will be returned since its register address is 0x00. Temperature Value Registers The ADT7481 has five registers to store the results of local and remote temperature measurements. These registers can only be written to by the ADC and read by the user over the SMBus. • The local temperature value register is at Address 0x00. • The Remote 1 temperature value high byte register is at Address 0x01, with the Remote 1 low byte register at Address 0x10. • The Remote 2 temperature value high byte register is at Address 0x30, with the Remote 2 low byte register at Address 0x33. • The Remote 2 temperature values can also be read from Address 0x01 for the high byte, and Address 0x10 for the low byte if Bit 3 of Configuration Register 1 is set to 1. • To read the Remote 1 temperature values, set Bit 3 of Configuration Register 1 to 0. • The power−on default value for all five registers is 0x00. Table 4. Configuration 1 Register (Read Address 0x03, Write Address 0x09) Bit Mnemonic Function 7 Mask Setting this bit to 1 masks all ALERTs on the ALERT pin. Default = 0 = ALERT enabled. This applies only if Pin 8 is configured as ALERT, otherwise it has no effect. 6 Mon/STBY Setting this bit to 1 places the ADT7481 in standby mode, that is, it suspends all temperature measurements (ADC). The SMBus remains active and values can be written to, and read from, the registers. However THERM and ALERT are not active in standby mode, and their states in standby mode are not reliable. Default = 0 = temperature monitoring enabled. 5 AL/TH This bit selects the function of Pin 8. Default = 0 = ALERT. Setting this bit to 1 configures Pin 8 as the THERM2 pin. 4 Reserved Reserved for future use. 3 Remote 1/2 Setting this bit to 1 enables the user to read the Remote 2 values from the Remote 1 registers. When default = 0, Remote 1 temperature values and limits are read from these registers. 2 Temp Range Setting this bit to 1 enables the extended temperature measurement range of −64°C to +191°C. When using the default = 0, the temperature range is 0°C to +127°C. 1 Mask R1 Setting this bit to 1 masks ALERTs due to the Remote 1 temperature exceeding a programmed limit. Default = 0. 0 Mask R2 Setting this bit to 1 masks ALERTs due to the Remote 2 temperature exceeding a programmed limit. Default = 0. Table 5. Configuration 2 Register (Address 0x24) Bit Mnemonic Function 7 Lock Bit Setting this bit to 1 locks all lockable registers to their current values. This prevents tampering with settings until the device is powered down. Default = 0. <6:0> Res Reserved for future use. Conversion Rate/Channel Selector Register The conversion rate/channel selector register for reads is at Address 0x04, and at Address 0x0A for writes. The four LSBs of this register are used to program the conversion times from 15.5 ms (Code 0x0A) to 16 seconds (Code 0x00). To program the ADT7481 to perform continuous measurements, set the conversion rate register to 0x0B. For example, a conversion rate of eight conversions/second means that beginning at 125 ms intervals, the device performs a conversion on the local and the remote temperature channels. This register can be written to, and read back from, the SMBus. The default value of this register is 0x08, giving a rate of 16 conversions per second. Using slower conversion times greatly reduces the device power consumption. Bit 7 in this register can be used to disable averaging of the temperature measurements. All temperature channels are measured by default. It is possible to configure the ADT7481 to measure the temperature of one channel only. This can be configured using Bit 4 and Bit 5 (see Table 6). |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |