13 / 20 page ![]() ADT7481 http://onsemi.com 13 Table 11. List of Registers Read Address (Hex) Lock Comment Power−On Default Mnemonic Write Address (Hex) 21 21 THERM Hysteresis 0000 1010 (0x0A) (10°C) Yes 22 22 Consecutive ALERT 0000 0001 (0x01) Yes 23 N/A Status Register 2 0000 0000 (0x00) No 24 24 Configuration 2 Register 0000 0000 (0x00) Yes 30 N/A Remote 2 Temperature Value High Byte 0000 0000 (0x00) No 31 31 Remote 2 Temp High Limit High Byte 0101 0101 (0x55) (85°C) Yes 32 32 Remote 2 Temp Low Limit High Byte 0000 0000 (0x00) (0°C) Yes 33 N/A Remote 2 Temperature Value Low Byte 0000 0000 (0x00) No 34 34 Remote 2 Temperature Offset High Byte 0000 0000 (0x00) Yes 35 35 Remote 2 Temperature Offset Low Byte 0000 0000 (0x00) Yes 36 36 Remote 2 Temp High Limit Low Byte 0000 0000 (0x00) (0°C) Yes 37 37 Remote 2 Temp Low Limit Low Byte 0000 0000 (0x00) (0°C) Yes 39 39 Remote 2 THERM Limit 0101 0101 (0x55) (85°C) Yes 3D N/A Device ID 1000 0001 (0x81) 3E N/A Manufacturer ID 0100 0001 (0x41) N/A 1. Writing to Address 0F causes the ADT7481 to perform a single measurement. It is not a data register as such, and it does not matter what data is written to it. Serial Bus Interface Control of the ADT7481 is achieved via the serial bus. The ADT7481 is connected to this bus as a slave device under the control of a master device. The ADT7481 has an SMBus timeout feature. When this is enabled, the SMBus will typically timeout after 25 ms of no activity. However, this feature is not enabled by default. Set Bit 7 (SCL timeout bit) of the consecutive alert register (Address 0x22) to enable the SCL timeout. Set Bit 6 (SDA timeout bit) of the consecutive alert register (Address 0x22) to enable the SDA timeout. The ADT7481 supports packet error checking (PEC) and its use is optional. It is triggered by supplying the extra clock for the PEC byte. The PEC byte is calculated using CRC−8. The frame check sequence (FCS) conforms to CRC−8 by the polynomial: C(x) + x8 ) x2 ) x1 ) 1 (eq. 1) Consult the SMBus 1.1 specification for more information (www.smbus.org). Addressing the Device In general, every SMBus device has a 7−bit device address, except for some devices that have extended, 10−bit addresses. When the master device sends a device address over the bus, the slave device with that address responds. The ADT7481 is available with one device address, 0x4C (1001 100b). An ADT7481−1 is also available. The only difference between the ADT7481 and the ADT7481−1 is the SMBus address. The ADT7481−1 has a fixed SMBus address of 0x4B (1001 011b). The addresses mentioned in this datasheet are 7−bit addresses. The R/W bit needs to be added to arrive at an 8−bit address. Other than the different SMBus addresses, the ADT7481 and the ADT7481−1 are functionally identical. The serial bus protocol operates as follows: The master initiates data transfer by establishing a start condition, defined as a high−to−low transition on the serial data line (SDATA) while the serial clock line (SCLK) remains high. This indicates that an address/data stream follows. All slave peripherals connected to the serial bus respond to the start condition and shift in the next eight bits, consisting of a 7−bit address (MSB first) plus a R/W bit, which determines the direction of the data transfer, that is, whether data will be written to, or read from, the slave device. The peripheral with the address corresponding to the transmitted address responds by pulling the data line low during the low period before the ninth clock pulse, known as the acknowledge bit. All other devices on the bus remain idle while the selected device waits for data to be read from or written to it. If the R/W bit is 0, the master writes to the slave device. If the R/W bit is 1, the master reads from the slave device. Data is sent over the serial bus in a sequence of nine clock pulses, eight bits of data followed by an acknowledge bit from the slave device. Transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, since a low−to−high transition when the clock is high may be interpreted as a stop signal. The number of data bytes that can be transmitted over the serial bus in a single read or write operation is limited only by what the master and slave devices can handle. When all data bytes have been read or written, stop conditions are established. In write mode, the master will pull the data line high during the tenth clock pulse to assert |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |