11 / 20 page ![]() ADT7481 http://onsemi.com 11 Table 8. Status Register 2 Bit Assignments Bit Mnemonic Function ALERT 7 Res Reserved for Future Use No 6 Res Reserved for Future Use No 5 Res Reserved for Future Use No 4 R2HIGH (Note 1) 1 When Remote 2 High Temperature Limit Tripped Yes 3 R2LOW (Note 1) 1 When Remote 2 Low Temperature Limit Tripped Yes 2 D2 OPEN (Note 1) 1 When Remote 2 Sensor Open Circuit Yes 1 R2THRM1 1 When Remote 2 THERM Limit Tripped No 0 ALERT 1 When ALERT Condition Exists No 1. These flags stay high until the status register is read, or they are reset by POR. The eight flags that can generate an ALERT are NOR’d together. When any flag is high, the ALERT interrupt latch is set and the ALERT output goes low (provided that the flag(s) is/are not masked out). Reading the Status 1 register will clear the five flags (Bit 6 through Bit 2) in Status Register 1, provided the error conditions that caused the flags to be set have gone away. Reading the Status 2 register will clear the three flags (Bit 4 through Bit 2) in Status Register 2, provided the error conditions that caused the flags to be set have gone away. A flag bit can only be reset if the corresponding value register contains an in−limit measurement, or if the sensor is good. The ALERT interrupt latch is not reset by reading the status register. It will be reset when the ALERT output has been serviced by the master reading the device address, provided the error condition has gone away and the status register flag bits have been reset. When Flag 1 and/or Flag 0 of Status Register 1, or Flag 1 of Status Register 2 are set, the THERM output goes low to indicate that the temperature measurements are outside the programmed limits. The THERM output does not need to be reset, unlike the ALERT output. Once the measurements are within the limits, the corresponding status register bits are reset automatically, and the THERM output goes high. The user may add hysteresis by programming Register 0x21. The THERM output will be reset only when the temperature falls below the THERM limit minus hysteresis. When Pin 8 is configured as THERM2, only the high temperature limits are relevant. If Flag 6 and Flag 4 of Status Register 1, or Flag 4 of Status Register 2 are set, the THERM2 output goes low to indicate that the temperature measurements are outside the programmed limits. Flag 5 and Flag 3 of Status Register 1, and Flag 3 of Status Register 2 have no effect on THERM2. The behavior of THERM2 is otherwise the same as THERM. Bit 0 of Status Register 2 gets set whenever the ALERT output is asserted low. Thus, the user need only read Status Register 2 to determine if the ADT7481 is responsible for the ALERT. This bit gets reset when the ALERT output gets reset. If the ALERT output is masked, then this bit is not set. Offset Register Offset errors may be introduced into the remote temperature measurement by clock noise or by the thermal diode being located away from the hot spot. To achieve the specified accuracy on this channel, these offsets must be removed. The offset values are stored as 10−bit, twos complement values. • The Remote 1 offset MSBs are stored in Register 0x11 and the LSBs are stored in Register 0x12 (low byte, left justified). • The Remote 2 offset MSBs are stored in Register 0x34 and the LSBs are stored in Register 0x35 (low byte, left justified). The Remote 2 offset can be written to, or read from, the Remote 1 offset registers if Bit 3 of the Configuration 1 register is set to 1. This bit should be set to 0 (default) to read the Remote 1 offset values. Only the upper two bits of the LSB registers are used. The MSB of the MSB offset register is the sign bit. The minimum offset that can be programmed is −128 °C, and the maximum is +127.75 °C. The value in the offset register is added to, or subtracted from, the measured value of the remote temperature. The offset register powers up with a default value of 0 °C and will have no effect unless the user writes a different value to it. Table 9. Sample Offset Register Codes Offset Value 0x11/0x34 0x12/0x35 −128°C 1000 0000 00 00 0000 −4°C 1111 1100 00 00 0000 −1°C 1111 1111 00 000000 −0.25°C 1111 1111 10 00 0000 0°C 0000 0000 00 00 0000 +0.25°C 0000 0000 01 00 0000 +1°C 0000 0001 00 00 0000 +4°C 0000 0100 00 00 0000 +127.75°C 0111 1111 11 00 0000 One−Shot Register The one−shot register is used to initiate a conversion and comparison cycle when the ADT7481 is in standby mode, after which the device returns to standby. Writing to the one−shot register address (0x0F) causes the ADT7481 to perform a conversion and comparison on both the local and the remote temperature channels. This is not a data register as such, and it is the write operation to Address 0x0F that causes the one−shot conversion. The data written to this address is irrelevant and is not stored. However the ALERT and THERM outputs are not operational in one−shot mode and should not be used. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |