| データシートサーチシステム |
|
DM6381F データシート(PDF) 16 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
DM6381F データシート(HTML) 16 Page - List of Unclassifed Manufacturers |
|
16 / 40 page ![]() DM336P V.34 Integrated Data/ Fax/Voice/Speakerphone Modem Device Set 16 Final Version: DM336P-DS-F02 August 15, 2000 d. DM6383 Configuration Modes The DM6383A is power-on in jumpless mode. The default configuration is set by loading the default value stored in 93C46 to Auto-configuration register. These values can be modified by software via the logical device configuration registers in DM Jumpless mode. This update value of new configuration is only valid temporarily and will be lost after an active PC Hardware Reset. Permanent changes of default configuration will be done by informing micro- controller to modify the content of 93C46 via Auto- configuration Register. The Plug and Play logic can operate through two configuration modes: One is DM Jumpless mode, the other, PnP mode. There are two operating methods between the two modes: First, setting hard configuration through Initiation Key sequences, second, setting hard configuration according to the register that is used, I/O Configuration Register or Auto-configuration Register. (1) The Initiation Key for Plug and Play The Plug and Play logical is in sequence on powering up and must be enabled by softwares. This is achieved by a predefined series of writes (32 I/O writes) to the Address port, which is called the Initiation Key. The proper series of the I/O writes is detected, then the Plug and Play read/write data ports are enabled. The Write sequence will be reset and must be issued from the beginning if any data mismatch occurs. The exact sequence for Initiation Key is listed below in hexadecimal notion. (2) PnP Initiation Key 6A, B5, DA, ED, F6, FB, 7D, BE, DF, 6F, 37, 1B, 0D, 86, C3, 61, B0, 58, 2C, 16, 8B, 45, A2, D1, E8, 74, 3A, 9D, CE, E7, 73, 39 (3) DM Initiation Key 68, 34, 1A, 8D, CB, E3, 71, B8, 5C, 2E, 97, 4B, 25, 92, C9, E4, 72, B9, DC, 6E, B7, 5B, 2D, 96, CB, 65, B2, D9, EC, 76, BB, 5D (4) Isolation Protocol A simple algorithm is used to isolate each Plug and Play card. This algorithm uses the signals on the ISA bus and requires lock-step operation between the Plug and Play hardware and the isolation software. STATE ISOLATION ID BIT = "1H" SD[1:0] = "01" LEAVE SD[7:0] IN HIGH-IMPEDANCE NO GET ONE BIT FROM SERIAL IDENTIFIER READ FROM SERIAL ISOLATION REGISTER YES WAIT FOR NEXT READ FROM SERIAL ISOLATION REGISTER SD[1:0] = "10" STATE SLEEP YES ID = 0 OTHER CARD ID = 1 READ ALL 72 BITS FROM SERIAL IDENTIFIER DRIVE "AAH" ON SD[7:0] AFTER I/O READ COMPLETES FETCH NEXT ID BIT FROM SERIAL IDENTIFIER ONE CARD ISOLATED NO YES NO YES LEAVE SD[7:0] IN HIGH IMPEDANCE NO DRIVE "55H" ON SD[7:0] |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |