15 / 32 page ![]() Data Sheet AD9913 Rev. E | Page 15 of 32 Table 5. Determining the Direction of the Linear Sweep Profile Pins [2:0] or CFR1 Bits [22:20] Linear Sweep Mode x001 Sweep off x011 Ramp up x101 Ramp down x111 Bidirectional ramp 1 x = don’t care. Note that if the part is used in parallel port programming mode, the sweep mode is only determined by the internal profile control bits, CFR1 [22:20]. If the part is used in serial port programming mode, either the internal profile control bits or the external profile select pins can work as the sweep control. CFR1 [27] selects between these two approaches. Setting the Slope of the Linear Sweep The slope of the linear sweep is set by the intermediate step size (delta tuning word) between S0 and E0 (see Figure 22) and the time spent (sweep ramp rate word) at each step. The resolution of the delta tuning word is 32 bits for frequency and 14 bits for phase. The resolution for the delta ramp rate word is 16 bits. In linear sweep mode, the user programs a rising delta word (RDW, Register 0x07) and a rising sweep ramp rate (RSRR, Register 0x08). These settings apply when sweeping from S0 to E0. The falling delta word (FDW, Register 0x07) and falling sweep ramp rate (FSRR, Register 0x08) apply when sweeping from E0 to S0. Note that if the auxiliary accumulator is allowed to overflow, an uncontrolled, continuous sweep operation occurs. To avoid this, the magnitude of the rising or falling delta word should be smaller than the difference between full-scale and the E0 value (full-scale − E0). For a frequency sweep, full-scale is 232 − 1. For a phase sweep, full-scale is 214 − 1. Figure 22 displays a linear sweep up and then down. This depicts the dwell mode (see CRF1 [8]). If the no-dwell bit, CFR1 [8], is set, the sweep accumulator returns to 0 upon reaching E0. S0 E0 TIME RDW FDW RSRR FSRR Δf, p Δf, p Δt Δt Figure 22. Linear Sweep Mode For a piecemeal or a nonlinear transition between S0 and E0, the delta tuning words and ramp rate words can be reprogram- med during the transition. The formulas for calculating the step size of RDW or FDW are SYSCLK f RDW Step Frequency 32 2 (MHz) 13 2 RDW Step Phase (radians) 11 2 45RDW Step Phase (degrees) The formula for calculating delta time from RSRR or FSRR is (Hz) / SYSCLK f RSRR t At 250 MSPS operation, (fSYSCLK =250 MHz). The minimum time interval between steps is 1/250 MHz × 1 = 4 ns. The maximum time interval is (1/250 MHz) × 65,535= 262 μs. Frequency Linear Sweep Example In linear sweep mode, when sweeping from low to high, the RDW is applied to the input of the auxiliary accumulator and the RSRR register is loaded into the sweep rate timer. The RDW accumulates at the rate given by the ramp rate (RSRR) until the output equals the upper limit in the linear sweep parameter register (Register 0x06). The sweep is then complete. When sweeping from high to low, the FDW is applied to the input of the auxiliary accumulator and the FSRR register is loaded into the sweep rate timer. The FDW accumulates at the rate given by the ramp rate (FSRR) until the output equals the lower limit in the linear sweep parameter register value (Register 0x06). The sweep is then complete. A phase sweep works in the same manner with fewer bits. To view sweep capabilities using the profile pins and the no- dwell bit, refer to Figure 23, Figure 24, and Figure 25. |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |