| データシートサーチシステム |
|
TSC2017 データシート(PDF) 32 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TSC2017 データシート(HTML) 32 Page - Texas Instruments |
|
32 / 38 page ![]() 1.6Vto3.6V 1.4V 0.3V 0V V DD t VDD_OFF_RAMP t VDD_OFF t VDD_ON_RAMP TSC2017 SBAS472 – DECEMBER 2009 www.ti.com Power-On Reset During TSC2017 power-up, an internal POR is automatically implemented. The POR brings the TSC to the default working condition. The TSC2017 senses the power-up curve and decides whether or not to implement a POR. Follow the power-on/off slope and interval requirements, as provided in the Electrical Characteristics, in order to ensure a proper POR of the TSC2017. Figure 37. Power-On Reset Timing Table 7. Timing Requirements for Figure 37 PARAMETER TEST CONDITIONS MIN MAX UNIT VDD off ramp TA = –40°C to +85°C 50 1,000,000 V/s VDD off time TA = –40°C to +85°C, VDD ≤ 0.4V 20 μs VDD on ramp TA = –40°C to +85°C 90 1,000,000 V/s 32 Submit Documentation Feedback Copyright © 2009, Texas Instruments Incorporated Product Folder Link(s): TSC2017 |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|