LM2507GR データシート(PDF) 13 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LM2507GR データシート(HTML) 13 Page - National Semiconductor (TI) |
|
13 / 22 page ![]() Functional Description (Continued) TABLE 3. READ — i80 CPU Interface Parameters No. Parameter Min Typ Max Units T1 MasterIN Set Up Time (A/D, RD*) and Data On Time 3.5 ns T2 MasterIN Hold Time (A/D, RD*) and Data Off Time 2.5 ns T3 Master Master Latency 7 MC Cycles T4 Slave Slave Latency 4 MC Cycles T5 Slave Read* Delay 1 MC Cycles T6 Slave Read Low Pulse Width 6 MC Cycles T7 Slave Data Set Up Time 5 ns T8 Slave Data Hold Time 5 ns T9 Slave Slave Read Latency 4 MC Cycles T10 Master MST Read Latency and INTR Delay 14 MC Cycles T11 Master Data Delay 13 41 ns T12 MasterOUT Data Valid after Strobe 1 7.5 ns T13 MasterOUT RD* active pulse width >50 ns T14 MasterOUT INTR De-assert 5 MC Cycles T15 MasterOUT Recovery Time, (Note 9) 5 ns T16 MasterOUT INTR Response 0 MC Cycles T17 Slave IDR Delay, IDR = High, Figure 13 4 MC Cycles SLAVE OUTPUT TIMING The Slave output recreates the transaction that was sent to the Master. However exact timing of the Slave output is not identical to the Master input. The active pulse (WR* and RD* output pulse) is a function of the MC cycle rate alone. The width applied on the Master input (assuming it meets set and hold requirements), is not regenerated by the Slave output. Also with WRITE transactions the output state is held until the next transaction requires them to be updated. For ex- ample after a i80 WRITE to CS1*, the A/D, DATAn, and CS1* output will remain static and hold their last state. CS1* will remain Low until a transaction to CS2* or a PowerDown event. This is acceptable to the target device as normally both an active CS and RD or WR signal is required. On the display side, the Slave can be configured through the IDR input to issue one or two read transactions to the peripheral. If configured for two read transactions, it will take longer for the INTR signal to be asserted from the Master to account for the time taken for the remote dummy read. Use of this mode allows for consistent behavior from the periph- eral regardless of the use of the MPL link (LM2507) or not. See Figure 13. Compatibility of target device’s timing requirements should be checked. Check that the active pulse is wide enough for the current settings. If the SLV output is too fast, a slower MC rate should be chosen (use a lower input CLK frequency). 20186034 FIGURE 13. Slave Output Timing with IDR = H www.national.com 13 |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |