13 / 16 page ![]() Setting item Description 12 DP-100 PRECAUTIONS FOR PROPER USE Condition Piping Wiring Others RUN mode MENU SETTING mode Connection Conditions in use for CE conformity Mounting Never use this product as a sensing device for personnel protection. In case of using sensing devices for personnel protection, use products which meet regulations and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. The DP-100 series is designed for use with non- corrosive gas. It cannot be used with liquid or corrosive gas. • • • Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Incorrect wiring will cause problems with operation. • • • • • • Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the keys with pointed or sharp objects. • • • • • • • If the mode selection key is pressed and held for 2 seconds in RUN mode, the mode will switch to MENU SETTING mode. If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. • • If connecting a commercially-available coupling to the pressure port, attach a 12 mm 0.472 in spanner (14 mm 0.551 in spanner for DP-100-E type) to the hexagonal section of the pressure port to secure it, and tighten at a torque of 9.8 N m or less. If it is tightened using excessive torque, it may damage the coupling or the pressure port. In addition, wrap sealing tape around the coupling when connecting it to prevent leaks. • Do not apply stress directly to the connection cable leader or to the connector. • The DP-100 series is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 61000-6-2 and the following condition must be met to conform to that standard. • The sensor should be connected less than 10 m 32.808 ft from the power supply. • The MS-DP1-1 sensor mounting bracket is available separately, and it should be used for mounting. When tightening the sensor to the sensor mounting bracket, use a tightening torque of 0.5 N m or less. • The MS-DP1-2 panel mounting bracket (optional) and the MS-DP1-3 front protection cover (optional) are also available. • Threshold value setting Zero-adjustment function Key lock function Peak hold / bottom hold function Stops key operations from being accepted. Comparative output 1 output mode setting Setting item Description Sets the output mode for comparative output 1. Unit switching Pressure unit can be changed. NO / NC switching Response time setting Comparative output 2 output mode setting (standard type only) Sets the output mode for comparative output 2. Display color switching for main display Analog voltage output / external input switching (multi-function type only) Sensor mounting bracket MS-DP1-1 (Optional) M3 (length 6 mm 0.236 in) screws with washers (Accessory for MS-DP1-1) Front protection cover MS-DP1-3 (Optional) Panel mounting bracket MS-DP1-2 (Optional) M3 (length 12 mm 0.472 in) tapping screw (Accessory for MS-DP1-2) Connector attached cable (CN-14A-C ) 12 mm 0.472 in spanner • This is the normal operating mode. Allows the color for the main display to be changed. The colors can be set to ‘red / green’ or ‘green / red’ to correspond to ON / OFF output, or it can be fixed at ‘red’ or ‘green’ all the time. Sets the response time. The response time can be selected from 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms and 5,000 ms. Sets normally open (NO) or normally closed (NC). Allows switching between analog voltage output and auto-reference input / remote zero-adjust- ment input. The threshold values for ON / OFF operation can be changed directly by pressing the increment key (UP) and the decrement key (DOWN). This forces the pressure value display to be reset to zero when the pressure port is open on the atmospheric pressure side. Displays the peak value and bottom value for fluctuating pressure. The peak value appears in the main display, and the bottom value appears in the sub display. |
|
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |