48 / 54 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 48 33813 6 Typical Applications 6.0.1 Output OFF Open Load Fault An output OFF open load fault is the detection and reporting of an open load when the corresponding output is disabled (input bit programmed to a logic low state). The output OFF open load fault is detected by comparing the drain-to-source voltage of the specific MOSFET output to an internally generated reference. Each output has one dedicated comparator for this purpose. Each output has an internal pull-down current source or resistor. The pull-down current sources are enabled on power-up and must be enabled for open load detect to function. In cases were the open load detect current is disabled, the status bit will always respond with logic 0. The device will only shut down the pull-down current in Sleep mode or when disabled via the SPI. During output switching, especially with capacitive loads, a false output OFF open load fault may be triggered. To prevent this false fault from being reported, an internal fault filter of 100 to 450 µs is incorporated. The duration for which a false fault may be reported is a function of the load impedance, RDS(ON), COUT of the MOSFET, as well as the supply voltage, VPWR. The rising edge of CSB triggers the built-in fault delay timer. The timer must time out before the fault comparator is enabled to detect a faulted threshold. Once the condition causing the open load fault is removed, the device resumes normal operation. The open load fault, however, will be latched in the output SO response register for the MCU to read. 6.0.2 Low Voltage Operation Low voltage condition (6.5 V< VPWR <9.0 V) will operate per the command word, however parameter tables may be out of specification and status reported on SO pin is not guaranteed. 6.0.3 Low Side Injector Driver Voltage Clamp Each Injector output of the 33813 incorporates an internal voltage clamp to provide fast turn-OFF and transient protection. Each clamp independently limits the drain-to-source voltage to VCL. The total energy clamped (EJ) can be calculated by multiplying the current area under the current curve (IA) times the clamp voltage (VCL) (see Figure 19). Characterization of the output clamps, using a repetitive pulse method at 1.0 A, indicates the maximum energy to be 100 mJ at 125 C junction temperature per output . Figure 19. Output Voltage Clamping 6.0.4 Reverse Battery Protection The 33813 device requires external reverse battery protection on the VPWR pin. All outputs consist of a power MOSFET with an integral substrate diode. During a reverse battery condition, current will flow through the load via the substrate diode. Under this condition load devices will turn on. If load reverse battery protection is desired, a diode must be placed in series with the load. Current Area (IA ) Clamp Energy (E J = IA x VCL ) Drain Voltage Time Drain-to-Source C lamp Voltage (VCL = 45 V) Drain Current (I D = 0.3 A) GND Drain-to-Source ON Voltage (VDS(O N)) 50 V) Drain-to-Source Clamp Voltage (VCL = 50 V) Drain-to-Source ON Voltage (VDS(ON)) Drain Voltage Clamp Energy (EJ = IA x VCL) GND Time Drain Current (ID = 0.3 A) |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |