| データシートサーチシステム |
|
AD7912AUJ-R2 データシート(PDF) 18 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7912AUJ-R2 データシート(HTML) 18 Page - Analog Devices |
|
18 / 32 page ![]() AD7912/AD7922 Rev. 0 | Page 18 of 32 MODES OF OPERATION The three modes of operation of the AD7912/AD7922 are normal mode, power-down mode, and daisy-chain mode. The mode of operation is selected by controlling the logic state of the CS signal. The point at which CS is pulled high after the conversion has been initiated determines whether the AD7912/AD7922 enter power-down mode or change to daisy- chain mode. Similarly, if already in daisy-chain mode, CS can control whether the device returns to normal operation or enters power-down mode. The user can also change from daisy- chain mode to normal mode by writing to the DIN pin, as outlined in the DIN Input section. Power-down mode is designed to provide flexible power management options and to optimize the ratio of power dissipation to throughput rate for different application requirements. Daisy-chain mode is intended for applications where fast throughput rate is not required and more than one AD7912/AD7922 have been connected in a daisy chain, as shown in Figure 33. NORMAL MODE Normal mode is intended for the fastest throughput rate performance. The user does not have to worry about any power-up time, because the AD7912/AD7922 remain fully powered all the time. Figure 26 shows the operation of the AD7912/AD7922 in this mode. The conversion is initiated on the falling edge of CS as described in the Serial Interface section. To ensure that the part remains fully powered up at all times, CS must remain low until at least 10 SCLK falling edges have elapsed after the falling edge of CS. If CS is brought high after the 10th SCLK falling edge and before the 12th SCLK falling edge, then the device enters daisy-chain mode, as shown in Figure 27. The conversion is terminated and DOUT goes back into three-state. If CS is brought high after the 13th SCLK falling edge, but before the end of tCONVERT, the conversion is terminated and DOUT goes back into three-state, but the part remains in normal mode. For the AD7922, 16 serial clock cycles are required to complete the conversion and access the complete conversion result. For the AD7912, a minimum of 14 serial clock cycles are required to complete the conversion and access the complete conversion result. CS can idle high until the next conversion or can idle low until CS returns high sometime prior to the next conversion (effectively idling CS low). Once a data transfer is complete (DOUT has returned to three-state), another conversion can be initiated after the quiet time, tQUIET, has elapsed by bringing CS low again. POWER-DOWN MODE Power-down mode is intended for use in applications where slower throughput rates are required. Either the ADC is powered down between each conversion, or a series of conversions can be performed at a high throughput rate and then the ADC is powered down for a relatively long duration between these bursts of several conversions. When the AD7912/ AD7922 are in power-down mode, all analog circuitry is powered down. To enter power-down mode, the conversion process must be interrupted by bringing CS high any time after the second falling edge of SCLK and before the 10th falling edge of SCLK, as shown in Figure 28. Once CS has been brought high in this window of SCLKs, then the part enters power-down mode, the conversion that was initiated by the falling edge of CS is termi- nated, and DOUT goes back into three-state. If CS is brought high before the second SCLK falling edge, then the part remains in normal mode and does not power down. This helps to avoid accidental power-down due to glitches on the CS line. To exit this mode of operation and power the AD7912/AD7922 up again, a dummy conversion is performed. On the falling edge of CS, the device begins to power up and continues to power up as long as CS is held low until after the falling edge of the 10th SCLK. The device is fully powered up once 16 SCLKs have elapsed and valid data results from the next conversion, as shown in Figure 29. If CS is brought high before the 10th falling edge of SCLK, then the AD7912/AD7922 go back into power- down mode. This helps to avoid accidental power-up due to glitches on the CS line or an inadvertent burst of 8 SCLK cycles while CS is low. Therefore, although the device might begin to power up on the falling edge of CS, it powers down again on the rising edge of CS, as long as this occurs before the 10th SCLK falling edge. |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |