143 / 205 page ![]() Data Sheet AD9546 Rev. 0 | Page 143 of 205 CAVEATS OF CASCADED DPLL OPERATION The recommendation is to avoid using reference synchronization when employing cascaded DPLL operation (see the Reference Synchronization section). When the profile targeted by the assigned inactive profile index becomes inactive, certain aspects of the target profile configuration still matter (even though the target profile is inactive), as follows: • The translation type (phase buildout or hitless—see the Translation Modes section). For phase buildout mode, the APLL associated with the primary DPLL must be in a calibrated and locked state. For hitless (internal) mode, the APLL associated with the primary DPLL must be in a calibrated and locked state, and the selected distribution path must be active (that is, a synchronization event has occurred (see the Distribution Output Clock Synchronization section) on the channel associated with the secondary DPLL). • The device uses the information related to the feedback configuration of the primary DPLL (even though the primary DPLL is effectively operating open loop, that is, holdover or freerun). • The user cannot specify fractional feedback division for the primary DPLL (that is, the device ignores the fractional portion of the feedback divider when operating in the cascaded DPLL configuration). Furthermore, the user must properly program the buildout N divider value in the targeted inactive profile (even if the targeted inactive profile is a hitless (internal) profile). See the DPLL Feedback Divider (N Divider) section for details relating to the buildout N divider. • The user cannot specify the external zero delay configuration for cascaded DPLL operation. • The device uses the information related to time stamp tagging according to the primary DPLL. Specifically, the tagging mode defined for the feedback path of the primary DPLL determines whether time stamp tags are available on the reference input path of the secondary DPLL. Thus, the targeted inactive profile for the primary DPLL must use a value of 2, 3, or 4 as the tag mode. In addition, the translation profile for the secondary DPLL must use a value of 1, 3, or 4 as the tag mode (see Table 86 regarding the tag modes). |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |