37 / 92 page ![]() AS1181 Functional description Datasheet • PUBLIC • Document Feedback DS001139 • v3-00 • 2026-Apr-01 37 / 92 / Bit Source Severity Interrupt type Description 9 over_temp Critical Level Over temperature (temp. > 125deg) Critical/safety interrupt. Indicates over temperature of the device. 10 idrive_overvoltage Info Pulse Overvoltage on any active channel Information interrupt to indicate voltage on LNx pins. If set, too high voltage on LNx is present. Information can be used to lower VLED via digital feedback. E.g.: Read-out AS1181 interrupt and lower DCDC output voltage providing VLED to AS1181. 11 idrive_undervoltage Info Pulse Undervoltage on any active channel Information interrupt to indicate voltage on LNx pins. If set a too low voltage on LNx is present. Information can be used to lower VLED via digital feedback. E.g.: Read-out AS1181 interrupt and increase DCDC output voltage providing VLED to AS1181. Possible to force it externally by decreasing VLED to its minimum AND having a too high forward voltage of the LED. 12 trigger_rate_error Critical Pulse Trigger rate error The strobe rate monitor measures the applied strobe signal frequency and compares it to the value stored in TD_TRATE_MAX register (Address 0x1A34). If the applied strobe signal is too fast, an interrupt is set to inform the host. Note that the strobe rate monitor is not available in direct PWM mode with 1 or 2 inputs. 13 ecc_error Critical Level OTP ECC error During power-on reset, the device checks the OTP block for any ECC errors (for example, if a bit has flipped). If an error is detected, the ecc_error interrupt is triggered. 14 idrive_ramp_error Critical Pulse Channel Ramp-down error Interrupt is set when a channel (LNx) current ramps down before ramp-up has been completed. 15 illum_duration_error Critical Pulse Illumination time error The illumination time monitor is continuously sampling the PWM ON time applied via both inputs and comparing the result with the value programmed in “TD_ILLUM_MAX register (Address 0x1A36)”. If the actual PWM ON time is longer than the value programmed the current sinks get turned off and the respective interrupt flag is set. |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |