44 / 104 page ![]() Diagnosis L9663 44/104 DocID028693 Rev 1 4.4 PSIx reverse voltage monitoring The PSIx sensor supply lines are monitored to detect a short circuit to battery if the PSIx line is switched on. Basic features: Reverse voltage monitoring with respect to VAS (or VBH during sync pulse) voltage with filter time Readable via SPI Figure 23. Timing for PSIx reverse voltage detection In case of a detected failure, a failure bit STBx in SR2 register is set to '1' (latched and cleared upon reading via SPI). After reset, the failure bit is reset to '0' 4.5 VAS under/over voltage monitoring The VAS voltage is monitored for under voltage and over voltage. Basic features: Under voltage comparator with filter time Over voltage comparator with filter time Readable via SPI Figure 24. Timing for VAS under voltage detection |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|