データシートサーチシステム
  Japanese  ▼
ALLDATASHEET.JP

X  

AM29PDL129H データシート(PDF) 29 Page - SPANSION

部品番号 AM29PDL129H
部品情報  128 Megabit (8 M x 16-Bit) CMOS 3.0 Volt-only, Page Mode Simultaneous Read/Write Flash Memory with Enhanced VersatileIO Control and Dual chip Enable
PDF  49 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
メーカー  SPANSION [SPANSION]
ホームページ  http://www.spansion.com
Logo SPANSION - SPANSION

AM29PDL129H データシート(HTML) 29 Page - SPANSION

Back Button AM29PDL129H Datasheet HTML 25Page - SPANSION AM29PDL129H Datasheet HTML 26Page - SPANSION AM29PDL129H Datasheet HTML 27Page - SPANSION AM29PDL129H Datasheet HTML 28Page - SPANSION AM29PDL129H Datasheet HTML 29Page - SPANSION AM29PDL129H Datasheet HTML 30Page - SPANSION AM29PDL129H Datasheet HTML 31Page - SPANSION AM29PDL129H Datasheet HTML 32Page - SPANSION AM29PDL129H Datasheet HTML 33Page - SPANSION Next Button
Zoom Inzoom in Zoom Outzoom out
 29 / 49 page
background image
November 2, 2005
Am29PDL129H
27
COMMAND DEFINITIONS
Enter /Exit Command Sequence
The region provides a secured data area containing a
random, eight word electronic serial number (ESN).
The system can access the region by issuing the
three-cycle Enter command sequence. The device
continues to access the region until the system issues
the four-cycle Exit command sequence. The Exit om-
mand sequence returns the device to normal opera-
tion. The SecSi Sector is not accessible when the
device is executing an Embedded Program or embed-
ded Erase algorithm. shows the address and data re-
quirements for both command sequences. See also
“SecSi Sector Flash Memory Region and Enter SecSi
Sector/Exit SecSi Sector Command Sequence” for fur-
ther information. Note that the ACC function and un-
lock bypass modes are not available when the SecSi
Sector is enabled.
Figure 5.
If the Persistent Sector Protection Mode Locking Bit is
verified as programmed without margin, the Persistent
Sector Protection Mode Locking Bit Program Com-
mand should be reissued to improve program margin.
If the SecSi Sector Protection Bit is verified as pro-
grammed without margin, the SecSi Sector Protection
Bit Program Command should be reissued to improve
program margin. µµAfter programming a PPB, two ad-
ditional cycles are needed to determine whether the
PPB has been programmed with margin. If the PPB
has been programmed without margin, the program
command should be reissued to improve the program
margin. Also note that the total number of PPB pro-
gram/erase cycles is limited to 100 cycles. Cycling the
PPBs beyond 100 cycles is not guaranteed.
After erasing the PPBs, two additional cycles are
needed to determine whether the PPB has been
erased with margin. If the PPBs has been erased with-
out margin, the erase command should be reissued to
improve the program margin.
PPB Lock Bit Status
Sector Protection Status The programming of
either the PPB or DYB for a given sector or sector
group can be verified by writing a Sector Protection
Status command to the device.
Note that there is no single command to independently
verify the programming of a DYB for a given sector
group.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49


データシート ダウンロード

Go To PDF Page


リンク URL



ALLDATASHEETはお客様のビジネスに役立ちますか?  [ DONATE ] 

Alldatasheetは   |   広告   |   お問い合わせ   |   プライバシーポリシー   |   データシートへのリンク    |   リンク交換   |   メーカーリスト
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com