| データシートサーチシステム |
|
L6759D データシート(PDF) 30 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6759D データシート(HTML) 30 Page - STMicroelectronics |
|
30 / 51 page ![]() Output voltage monitoring and protection L6759D 30/51 Doc ID 023240 Rev 1 Equation 13 where N is the number of phases and DCR the DC resistance of the inductors. RG should be designed in worst-case conditions ● Design the RIMON in order to have the IMON pin voltage to 1.24 V at the IMAX current specified by the design. It results: Equation 14 where IMAX is max. current requested by the processor (see Intel documentation for details) ● Design the RILIM in order to have the ILIM pin voltage to 2.5 V at the IOC_TOT current specified above. It results: Equation 15 where IOC_TOT is the overcurrent switch-over threshold previously defined ● Adjust the defined values according to the bench-test of the application ● CILIM in parallel to RILIM can be added with a proper time constant to prevent false OC tripping and/or delay ● CIMON in parallel to RIMON can be added to adjust the averaging interval for the current reporting and/or to adjust the DPM latencies. Additionally, it can be increased to prevent false Total-OC tripping during DVID. Note: This is the typical design flow. Custom design and specifications may require different settings and ratios between the per-phase OC threshold and the total current OC threshold. Applications with big ripple across inductors may be required to set per-phase OC to values different than 110%: the design flow should be modified accordingly. 7.2.2 Overcurrent and power states When the controller receives the SetPS command through the SVI interface, it automatically changes the number of working phases. In particular, the maximum number of phases in which L6759D may work in > PS00h is limited to 2, regardless of the number N configured in PS00h. The OC level is then scaled as the controller enters > PS00h, as per Table 9. R G 1.1 I OC_TOT ⋅ () DCR ⋅ NI ⋅ OCTH -------------------------------------------------------------- = R IMON 1.24V R G ⋅ I MAX DCR ⋅ --------------------------------- = R ILIM 2.5V R G ⋅ I OC_TOT DCR ⋅ ----------------------------------------- = Table 9. Multi-phase section OC scaling and power states Power state [Hex] N OC level (VOC_TOT) 00h 2 to 3 2.500 V |
|
リンク URL |
| ALLDATASHEETはお客様のビジネスに役立ちますか? [ DONATE ] |
Alldatasheetは | 広告 | お問い合わせ | プライバシーポリシー | データシートへのリンク | リンク交換 | メーカーリスト All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |